2 Specifications
MODEL
INDOOR
CS-RE18JKE
CS-RE24JKE
OUTDOOR
CU-RE18JKE
CU-RE24JKE
Performance Test Condition
EUROVENT
EUROVENT
Power Supply
Phase, Hz
Single, 50
Single, 50
V
230
230
Min.
Mid.
Max.
Min.
Mid.
Max.
C
o
o
l
i
n
g
Capacity
kW
0.90
5.00
6.00
0.90
6.80
8.10
BTU/h
3070
17100
20500
3070
23200
27600
Kcal/h
770
4300
5160
770
5850
6970
Running Current
A
—
6.7
—
—
9.7
—
Input Power
W
215
1.47k
2.03k
350
2.12k
2.70k
Annual Consumption
kWh
—
735
—
—
1060
—
EER
W/W
4.19
3.40
2.96
2.57
3.21
3.00
Kcal/hW
3.58
2.93
2.54
2.20
2.76
2.58
Power Factor
%
—
95
—
—
95
—
Indoor Noise (H / L / QLo)
dB-A
44 / 37
47 / 38
Power Level dB
60
63
Outdoor Noise (H / L)
dB-A
47
52
Power Level dB
61
66
H
e
a
t
i
n
g
Capacity
kW
0.90
5.80
8.00
0.90
8.60
9.90
BTU/h
3070
19800
27300
3070
29300
33800
Kcal/h
770
4990
6880
770
7400
8510
Running Current
A
—
7.0
—
—
12.1
—
Input Power
W
245
1.54k
2.60k
360
2.66k
3.20k
COP
W/W
3.67
3.77
3.08
2.50
3.23
3.09
Kcal/hW
3.14
3.24
2.65
2.14
2.78
2.66
Power Factor
%
—
96
—
—
96
—
Indoor Noise (H / L / QLo)
dB-A
44 / 37
47 / 38
Power Level dB
60
63
Outdoor Noise (H / L)
dB-A
47
52
Power Level dB
61
66
Low Temp.: Capacity (kW) / I.Power (W) / COP
5.80 / 2.35k / 2.47
7.17 / 2.83k / 2.53
Extr Low Temp.: Capacity (kW) / I.Power (W) / COP
4.98 / 2.41k / 2.07
6.13 / 2.86k / 2.14
Max Current (A) / Max Input Power (W)
11.7 / 2.60k
14.6 / 3.20k
Starting Current (A)
7.0
12.1
Compressor
Type
Hermetic Motor
Hermetic Motor
Motor Type
Brushless (4-poles)
Brushless (4-poles)
Output Power
W
900
1.7k
Summary of Contents for CS-E18JKEW
Page 9: ...9 4 Location of Controls and Components 4 1 Indoor Unit 4 2 Outdoor Unit 4 3 Remote Control ...
Page 10: ...10 5 Dimensions 5 1 Indoor Unit Remote Control ...
Page 11: ...11 5 2 Outdoor Unit 5 2 1 CU RE18JKE ...
Page 12: ...12 5 2 2 CU RE24JKE ...
Page 13: ...13 6 Refrigeration Cycle Diagram ...
Page 14: ...14 7 Block Diagram 7 1 CS RE18JKE CU RE18JKE ...
Page 15: ...15 7 2 CS RE24JKE CU RE24JKE ...
Page 16: ...16 8 Wiring Connection Diagram 8 1 Indoor Unit ...
Page 17: ...17 8 2 Outdoor Unit 8 2 1 CU RE18JKE ...
Page 18: ...18 8 2 2 CU RE24JKE ...
Page 19: ...19 9 Electronic Circuit Diagram 9 1 Indoor Unit ...
Page 20: ...20 9 2 Outdoor Unit 9 2 1 CU RE18JKE ...
Page 21: ...21 9 2 2 CU RE24JKE ...
Page 22: ...22 10 Printed Circuit Board 10 1 Indoor Unit 10 1 1 Main Printed Circuit Board ...
Page 23: ...23 10 1 2 Power Printed Circuit Board 10 1 3 Indicator Printed Circuit Board ...
Page 24: ...24 10 2 Outdoor Unit 10 2 1 Main Printed Circuit Board 10 2 1 1 CU RE18JKE ...
Page 25: ...25 10 2 2 Main Printed Circuit Board 10 2 2 1 CU RE24JKE ...
Page 26: ...26 10 2 3 Power Printed Circuit Board 10 2 3 1 CU RE24JKE ...
Page 76: ...76 16 1 3 To remove power electronic controller ...
Page 77: ...77 16 1 4 To remove discharge grille 16 1 5 To remove control board ...
Page 78: ...78 16 1 6 To remove cross flow fan and indoor fan motor ...
Page 79: ...79 ...
Page 90: ...90 18 Exploded View and Replacement Parts List 18 1 Indoor Unit ...