84
16.1.3 Detaching the Fan
1 First detach the Upper and Inner Casing
(16.1.1)
2 Disengage the 4 catches (2 each on the left
and right) on the Air Guide.
3 Use a 2.5 mm hexagonal wrench to loosen
the 2 bolts connecting the Fan Motor and Fan,
detach the shaft connecting the Fan Motor
and Fan, loosen the screw holding the Fan
and detach the Fan.
16.1.4 Detaching the Fan Motor and Drain Motor
Fan Motor
1 First detach the Upper and Inner Casing
(16.1.1) and the Fan (16.1.3).
2 Unscrew the 4 screws holding the Fan Motor
and detach it.
Drain Motor
1 First detach the Upper and Inner Casing
(16.1.1) and the Fan (16.1.3).
2 From the Fan Motor side, undo the 2 hexagon
bolts and detach the Drain Motor.