background image

AAF

8

To learn more...

Ope

Use th
DBT : 
WBT : 

C

H

Operation mode

AUTO : 

During operation mode selection the POWER indicator blinks.

• Unit selects operation mode every 10 minutes according to setting temperature and room temperature.

HEAT : 

Unit takes a while to warm up. The POWER indicator blinks during this operation.

COOL :   

Use curtains to screen off sunlight and outdoor heat to reduce power consumption during COOL mode.

DRY : 

Unit operates at low fan speed to give a gentle cooling operation.

FAN

 

:

 To circulate air in the room

nanoe-G in-

fi

 lter deactivation

Depending on the unit’s accumulated operation time, nanoe-G in-

fi

 lter deactivation may activate only once a day after 

the unit turned off.
To remove the moisture left in the internal parts, the fan will operate for 30 minutes with louver opened slightly. This 
process only applicable when the unit is operated in COOL/DRY mode before turned off.Then, nanoe-G deactivates 
viruses/bacteria on the 

fi

 lter for 2 hours with fan stopped and louver closed.

Do not turn off the power supply during this operation. After power failure, this operation will not resume.

ECONAVI and AUTO COMFORT

ECONAVI

AUTO

COMFORT

or

Note

AIR SWING

When manual AIR SWING is selected, 
the ECONAVI and AUTO COMFORT 
operations will be cancelled.

The unit will start to initialise
(for approximately 1 minute)

The human activity sensor 
and the sunlight sensor will 
start to detect.

Human activity sensor operation

Low activity

Normal activity

Human

Mode

Set 

temperature

High activity

Absent

ECONAVI 

; Detecting human presence and activity, the unit controls room temperature to save energy.

Low activity

Normal activity

Human

Mode

Set 

temperature

High activity

Absent

Set 
Fan Speed

AUTO COMFORT 

; Detecting human presence and activity, the unit controls room temperature to keep human 

ECONAVI and AUTO COMFORT take advantage of 
the human nature that human being takes time to feel 
the temperature rise during low activity level; the unit 
adjusts temperature to maximise energy saving 
without sacrificing the comfort.

comfortable consistently.

HEAT

COOL/DRY

HEAT

COOL/DRY

*  During low activity, fan speed 1 tap up for first 15 minutes or until set temperature is reached.
**  During human absence, maximum fan speed for COOL/DRY mode is medium fan.

-2 °C

-2 °C

+1 °C

+2 °C

-1 °C

Low activity

Human

Mode

Precise control of temperature during low activity to maximise energy saving.

Set 
temperature

COOL/DRY

ECONAVI and AUTO COMFORT 

+1 tap

”0HGLXP)DQ

+1 tap*

-2 °C

+0.3 °C

-2 °C

+2 °C

+1 °C

Sunl

HEAT

COO

ECO

Mode

• In a 

The h

The u
horizo

• The 

rang

• The 

-  mis
-  mis

• Do n

area

F569361_EN.indd   8

F569361_EN.indd   8

7/9/2013   8:48:47 AM

7/9/2013   8:48:47 AM

Summary of Contents for CS-E12PKR

Page 1: ...CU E9PKR CU E12PKR CU E15PKR CU E18PKR CU E21PKR CU E24PKR CU E28PKR Operating Instructions Air Conditioner Operating Instructions Air Conditioner Thank you for purchasing Panasonic Air Conditioner Installation instructions attached Before operating the unit read these operating instructions thoroughly and keep them for future reference ...

Page 2: ...onditioner ensures to deliver cool or warm air to you and keeps the room consistently comfortable with minimum energy consumption See To learn more for details nanoe G Deactivates harmful micro organisms such as viruses bacteria etc to keep air clean It also deactivates viruses and bacteria on the filter to keep inside of the unit clean ...

Page 3: ...ure may save energy HEAT 20 C 24 C COOL 26 C 28 C DRY 1 C 2 C lower than room temperature The set temperature selection range can be customized according to requirement Please consult authorised dealer To dim or restore the unit s indicator brightness press and hold for 5 seconds Use remote control within 8 m from the remote control receiver of the indoor unit The illustrations in this manual are ...

Page 4: ...Children should be supervised to ensure that they do not play with the appliance Please consult authorised dealer or specialist to clean the internal parts repair install remove and reinstall the unit Improper installation and handling will cause leakage electric shock or fire Confirm with authorised dealer or specialist on usage of any specified refrigerant type Using refrigerant type other than ...

Page 5: ...t wash the indoor unit with water benzine thinner or scouring powder to avoid damage or corrosion at the unit Do not use for preservation of precise equipment food animals plants artwork or other objects This may cause quality deterioration etc Do not use any combustible equipment in front of the airflow outlet to avoid fire propagation Do not expose plants or pet directly to airflow to avoid inju...

Page 6: ...This operation reduces airflow noise How to use Auto OFF ON button Use when remote control is misplaced or a malfunction occurs Raise the front panel To use in AUTO mode press the button once To use in COOL mode press and hold the button until 1 beep is heard then release To use in HEAT mode press and hold the button until 1 beep is heard then release And press again until 2 beeps are heard then r...

Page 7: ...tion The vertical louver swings left right after the temperature rises Do not adjust the louver by hand 7 English To set the timer 2 sets of ON and OFF timers are available to turn ON or OFF the unit at different preset times 2 1 3 1 Select ON or OFF timer Example OFF at 22 00 Each time pressed Cancel 2 Set the time 3 Confirm TIMER To cancel ON or OFF timer press or to select respective or then pr...

Page 8: ...FORT or Note AIR SWING When manual AIR SWING is selected the ECONAVI and AUTO COMFORT operations will be cancelled The unit will start to initialise for approximately 1 minute The human activity sensor and the sunlight sensor will start to detect Human activity sensor operation Low activity Normal activity Human Mode Set temperature High activity Absent ECONAVI Detecting human presence and activit...

Page 9: ...as cloudy night The human activity sensor will also scan for area of heat source and movement in a room Detection area Human activity indicator 120º 7m At left area At center multiple area At right area The unit judges human activity area for a few seconds before indicator updates Based on area activeness horizontal airflow direction louver will adjust either fix at predetermined position or swing...

Page 10: ...UIET Insert at both sides 1 Press both ends of the front panel 3 Close down 2 nanoe G Generator Every 6 months Clean with dry cotton bud Do not touch during operation Air filters Every 2 weeks Wash rinse the filters gently with water to avoid damage to the filter surface Dry the filters thoroughly under shade away from fire or direct sunlight Replace any damaged filters Remove air filter Attach ai...

Page 11: ... during operation The unit is in Demand Response Mode Check the following before calling for servicing Symptom Check Operation in HEAT COOL mode is not working efficiently Set the temperature correctly Close all doors and windows Clean or replace the filters Clear any obstruction at the air inlet and air outlet vents Noisy during operation Check if the unit has been installed at an incline Close t...

Page 12: ...o discard these items please contact your local authorities or dealer and ask for the correct method of disposal Pb Note for the battery symbol bottom two symbol examples This symbol might be used in combination with a chemical symbol In this case it complies with the requirement set by the Directive for the chemical involved F569361 FA0413 0 Printed in Malaysia Panasonic Corporation Website http ...