SAFETY PRECAUTIONS

To prevent personal injury, injury to others, or property 

damage, please comply with the following.

Incorrect operation due to failure to follow instructions below 

may cause harm or damage, the seriousness of which is 

classifi ed as below:

  

WARNING

WARNING

This sign warns of death or serious injury.

  

CAUTION

CAUTION

This sign warns of injury or damage to property.

The instructions to be followed are classifi ed by the following 
symbols:

This symbol denotes an action that is PROHIBITED.

 

 

 

These symbols denote an actions that is 

COMPULSORY.

 

WARNING

WARNING

INDOOR UNIT AND OUTDOOR UNIT

This appliance is not intended for use by 

persons (including children) with reduced 

physical, sensory or mental capabilities, or lack 

of experience and knowledge, unless they have 

been given supervision or instruction concerning 

use of the appliance by a person responsible for 

their safety. Children should be supervised to 

ensure that they do not play with the appliance.
Please consult authorized dealer or specialist to 

clean the internal parts, repair, install, remove 

and reinstall the unit. Improper installation and 

handling will cause leakage, electric shock or 

fi re.
Confi rm to authorized dealer or specialist on 

usage of specifi ed refrigerant type. Using of 

refrigerant other than the specifi ed type may 

cause product damage, burst and injury etc.
Do not install the unit in a potentially explosive 

or fl ammable atmosphere. Failure to do so could 

result in fi re.
Do not insert your fi ngers or other 

objects into the air conditioner indoor 

or outdoor unit, rotating parts may 

cause injury.
Do not touch the outdoor unit during lightning, it 

may cause electric shock.
Do not expose yourself directly to cold air for a 

long period to avoid excess cooling.
Do not sit or step on the unit, you may 

fall down accidentally.

REMOTE CONTROL

Do not allow infants and small children to play 

with the remote control to prevent them from 

accidentally swallowing the batteries.

POWER SUPPLY

Do not use a modifi ed cord, 

joint cord, extension cord or 

unspecifi ed cord to prevent 

overheating and fi re. 
To prevent overheating, fi re or electric shock:

•  Do not share the same power outlet with other 

equipment.

•  Do not operate with wet hands.

•  Do not over bend the power supply cord.

•  Do not operate or stop the unit by inserting or 

pulling out the power plug.

Air Inlet

Air Inlet

Air Outlet

Air Outlet

Air Outlet

Air Outlet

Air Inlet

Air Inlet

Remote

Control

Power

Supply

Indoor 

Unit

Outdoor 

Unit

Summary of Contents for CS-E12NKDW

Page 1: ...W CU E18NKD Multi Split Outdoor Unit U 2E15GBE U 2E18CBPG U 3E18JBE U 4E23JBE ENGLISH 2 12 Before operating the unit read these operating instructions thoroughly and keep them for future reference QUICK GUIDE QUICK GUIDE КРАТКАЯ КОРОТКА ІНСТРУКЦІЯ ҚЫСҚАША НҰСҚАУЛЫҚ Panasonic Appliances Air Conditioning Malaysia Sdn Bhd 2012 Unauthorized copying and distribution is a violation of law ...

Page 2: ... single outdoor unit Room A Room A Room B Room B Room C Room C Multi Split Outdoor Unit Multi Split Outdoor Unit INDOOR UNIT INDOOR UNIT It is possible to operate the indoor units individually or simultaneously The operation mode priority is given to the first unit that turned on During operation heating and cooling mode can not be activated at the same time for different indoor unit The power ind...

Page 3: ...Temperature C Indoor Outdoor DBT WBT DBT WBT COOLING Max 32 23 43 26 Min 16 11 16 11 HEATING Max 30 24 18 Min 16 5 6 Multi Split Outdoor Unit Temperature C Indoor Outdoor Outdoor U 2E15GBE U 2E18CBPG U 3E18JBE U 4E23JBE DBT WBT DBT WBT DBT WBT COOLING Max 32 23 43 26 46 26 Min 16 11 16 11 10 HEATING Max 30 24 18 24 18 Min 16 10 11 15 16 DBT Dry bulb temperature WBT Wet bulb temperature ...

Page 4: ...cause leakage electric shock or fire Confirm to authorized dealer or specialist on usage of specified refrigerant type Using of refrigerant other than the specified type may cause product damage burst and injury etc Do not install the unit in a potentially explosive or flammable atmosphere Failure to do so could result in fire Do not insert your fingers or other objects into the air conditioner in...

Page 5: ...not use rechargeable Ni Cd batteries It may damage the remote control To prevent malfunction or damage of the remote control Remove the batteries if the unit is not going to be used for a long period of time New batteries of the same type must be inserted following the polarity stated POWER SUPPLY Do not pull the cord to disconnect the plug to prevent electric shock WARNING WARNING POWER SUPPLY If...

Page 6: ... room temperature For Single Split System Unit selects operation mode every 3 hours according to temperature setting outdoor and room temperature For Multi Split System HEAT mode To enjoy warm air Unit takes a while to warm up The power indicator blinks during this operation COOL mode To enjoy cool air Use curtains to screen off sunlight and outdoor heat to reduce power consumption during cool mod...

Page 7: ...contact However you can adjust the louver direction manually Multi Split System Function not applicable 9 TO SWITCH BETWEEN POWERFUL QUIET POWERFUL QUIET QUIET POWERFUL NORMAL POWERFUL TO REACH TEMPERATURE QUICKLY POWERFUL Single Split System This operation stops automatically after 20 minutes Multi Split System Press the button again or turn OFF the unit to stop this operation QUIET TO ENJOY QUIE...

Page 8: ...ll be displayed and will be activated in sequence When ON Timer is set the unit may start earlier up to 35 minutes before the actual set time in order to achieve the desired temperature on time Timer operation is based on the clock set in the remote control and repeats daily once set For clock setting please refer to Remote Control Preparation on the back cover 12 Press and hold for 5 seconds to d...

Page 9: ...nit gently with a soft dry cloth 2 FRONT PANEL Remove Front Panel Raise and pull to remove the front panel Wash gently and dry Close Front Panel 2 1 1 1 Press down both ends of the front panel to close it 2 Press at center of the front panel to close it securely CS E18NKDW 3 REMOTE CONTROL RECEIVER 4 ALUMINIUM FIN 5 HUMAN ACTIVITY SENSOR 6 HORIZONTAL AIRFLOW DIRECTION LOUVER E7NKDW E9NKDW E12NKDW ...

Page 10: ...evaporation occurs on pipes TIMER indicator is always on The timer setting repeats daily once set POWER Indicator blinks during HEAT mode with no warm air supply and louver is closed The unit is in defrost mode and AIR SWING is set to AUTO Indoor fan stops occasionally during heating operation To avoid unintended cooling effect POWER Indicator blinks before the unit is switched on This is prelimin...

Page 11: ...th general household waste For proper treatment recovery and recycling of old products and used batteries please take them to applicable collection points in accordance with your national legislation and the Directives 2002 96 EC and 2006 66 EC By disposing of these products and batteries correctly you will help to save valuable resources and prevent any potential negative effects on human health ...

Page 12: ...n on the Restriction Of the use of certain Hazardous Substances in electrical and electronic equipment TR on RoHS The content of hazardous substance with the exemption of the applications listed in the Annex 2 of TR on RoHS 1 Lead Pb not over 0 1wt or 1000wt ppm 2 Cadmium Cd not over 0 01wt or 100wt ppm 3 Mercury Hg not over 0 1wt or 1000wt ppm 4 Hexavalent chromium Cr6 not over 0 1wt or 1000wt pp...