background image

ENGLISH

7

5

TO ADJUST VERTICAL AIRFLOW DIRECTION 

(5 OPTIONS)

AIR SWING

•  Keeps the room ventilated.

•  In COOL/DRY mode, if AUTO is set, the louver swing 

up/down automatically.

•  In HEAT mode, if AUTO is set, the louver fi x at 

predetermined position.

6

TO ADJUST VERTICAL AIRFLOW DIRECTION 

(5 OPTIONS)

AIR SWING

•  Keeps the room ventilated.

•  In COOL/DRY mode, if AUTO is set, the louver swing 

left/right and up/down automatically.

•  In HEAT mode, if AUTO is set, the horizontal louver fi x at 

predetermined position. The vertical louver swing left/right 

after the temperature rises.

7

TO PURIFY THE AIR

NANOE-G

•  Removes/deactivates harmful micro-organisms such as 

viruses, bacteria, etc.

•  Can be activated even when the unit is turned off. In this 

condition, fan speed and air swing cannot be adjusted.

•  nanoe-G starts automatically with the unit switched on 

with 

OFF/ON

.

8

TO IMPROVE HUMIDITY AND MOISTURE LEVEL

Single Split System
•  This operation reduces air dryness and provides you with 

a comfortable living environment during COOL mode only.

•  When vertical airfl ow direction is set to AUTO, it stops at 

lower position to avoid cold air contact. However, you can 

adjust the louver direction manually.

Multi Split System
•  Function not applicable.

9

TO SWITCH BETWEEN POWERFUL & QUIET

POWERFUL/

QUIET

QUIET

POWERFUL

NORMAL

POWERFUL

TO REACH TEMPERATURE 

QUICKLY

POWERFUL

•  Single Split System: This operation stops 

automatically after 20 minutes. 

•  Multi Split System: Press the button again or 

turn OFF the unit to stop this operation.

QUIET

TO ENJOY QUIET 

OPERATION

QUIET

•  This operation reduces airfl ow noises.

10

 

11

TO MONITOR  HUMAN PRESENCE & 

ACTIVITY FOR ENERGY SAVING & 

COMFORT

ECONAVI

To optimize energy 

saving

ECONAVI

AUTO

COMFORT

To maximize comfort

AUTO COMFORT

Set Fan Speed

-2°C

-1°C

HEAT Mode

Set Temperature

+0.3°C

Heat Source & Movement

Normal

High

Low

None

Set Fan Speed

 Medium

Fan

+1 tap*

+2°C

-1°C

+1 tap

+0.3°C

COOL/DRY Mode

Set Temperature

* For first 15 minutes or until set temperature is reached.
•  The human activity sensor may not detect moving objects 

further than 7m away or beyond detection angle.

•  The human activity sensor sensitivity is infl uenced by 

indoor unit location, movement speed, temperature range, 

etc.

•  The human activity sensor may: 

-  Mistakenly detects an object with heat source & 

movement similar to human, such as pets, etc. as 

human being.

-  Mistakenly detects as non-heat source & movement if 

a person stays motionless for certain period of time.

Summary of Contents for CS-E12NKDW

Page 1: ...W CU E18NKD Multi Split Outdoor Unit U 2E15GBE U 2E18CBPG U 3E18JBE U 4E23JBE ENGLISH 2 12 Before operating the unit read these operating instructions thoroughly and keep them for future reference QUICK GUIDE QUICK GUIDE КРАТКАЯ КОРОТКА ІНСТРУКЦІЯ ҚЫСҚАША НҰСҚАУЛЫҚ Panasonic Appliances Air Conditioning Malaysia Sdn Bhd 2012 Unauthorized copying and distribution is a violation of law ...

Page 2: ... single outdoor unit Room A Room A Room B Room B Room C Room C Multi Split Outdoor Unit Multi Split Outdoor Unit INDOOR UNIT INDOOR UNIT It is possible to operate the indoor units individually or simultaneously The operation mode priority is given to the first unit that turned on During operation heating and cooling mode can not be activated at the same time for different indoor unit The power ind...

Page 3: ...Temperature C Indoor Outdoor DBT WBT DBT WBT COOLING Max 32 23 43 26 Min 16 11 16 11 HEATING Max 30 24 18 Min 16 5 6 Multi Split Outdoor Unit Temperature C Indoor Outdoor Outdoor U 2E15GBE U 2E18CBPG U 3E18JBE U 4E23JBE DBT WBT DBT WBT DBT WBT COOLING Max 32 23 43 26 46 26 Min 16 11 16 11 10 HEATING Max 30 24 18 24 18 Min 16 10 11 15 16 DBT Dry bulb temperature WBT Wet bulb temperature ...

Page 4: ...cause leakage electric shock or fire Confirm to authorized dealer or specialist on usage of specified refrigerant type Using of refrigerant other than the specified type may cause product damage burst and injury etc Do not install the unit in a potentially explosive or flammable atmosphere Failure to do so could result in fire Do not insert your fingers or other objects into the air conditioner in...

Page 5: ...not use rechargeable Ni Cd batteries It may damage the remote control To prevent malfunction or damage of the remote control Remove the batteries if the unit is not going to be used for a long period of time New batteries of the same type must be inserted following the polarity stated POWER SUPPLY Do not pull the cord to disconnect the plug to prevent electric shock WARNING WARNING POWER SUPPLY If...

Page 6: ... room temperature For Single Split System Unit selects operation mode every 3 hours according to temperature setting outdoor and room temperature For Multi Split System HEAT mode To enjoy warm air Unit takes a while to warm up The power indicator blinks during this operation COOL mode To enjoy cool air Use curtains to screen off sunlight and outdoor heat to reduce power consumption during cool mod...

Page 7: ...contact However you can adjust the louver direction manually Multi Split System Function not applicable 9 TO SWITCH BETWEEN POWERFUL QUIET POWERFUL QUIET QUIET POWERFUL NORMAL POWERFUL TO REACH TEMPERATURE QUICKLY POWERFUL Single Split System This operation stops automatically after 20 minutes Multi Split System Press the button again or turn OFF the unit to stop this operation QUIET TO ENJOY QUIE...

Page 8: ...ll be displayed and will be activated in sequence When ON Timer is set the unit may start earlier up to 35 minutes before the actual set time in order to achieve the desired temperature on time Timer operation is based on the clock set in the remote control and repeats daily once set For clock setting please refer to Remote Control Preparation on the back cover 12 Press and hold for 5 seconds to d...

Page 9: ...nit gently with a soft dry cloth 2 FRONT PANEL Remove Front Panel Raise and pull to remove the front panel Wash gently and dry Close Front Panel 2 1 1 1 Press down both ends of the front panel to close it 2 Press at center of the front panel to close it securely CS E18NKDW 3 REMOTE CONTROL RECEIVER 4 ALUMINIUM FIN 5 HUMAN ACTIVITY SENSOR 6 HORIZONTAL AIRFLOW DIRECTION LOUVER E7NKDW E9NKDW E12NKDW ...

Page 10: ...evaporation occurs on pipes TIMER indicator is always on The timer setting repeats daily once set POWER Indicator blinks during HEAT mode with no warm air supply and louver is closed The unit is in defrost mode and AIR SWING is set to AUTO Indoor fan stops occasionally during heating operation To avoid unintended cooling effect POWER Indicator blinks before the unit is switched on This is prelimin...

Page 11: ...th general household waste For proper treatment recovery and recycling of old products and used batteries please take them to applicable collection points in accordance with your national legislation and the Directives 2002 96 EC and 2006 66 EC By disposing of these products and batteries correctly you will help to save valuable resources and prevent any potential negative effects on human health ...

Page 12: ...n on the Restriction Of the use of certain Hazardous Substances in electrical and electronic equipment TR on RoHS The content of hazardous substance with the exemption of the applications listed in the Annex 2 of TR on RoHS 1 Lead Pb not over 0 1wt or 1000wt ppm 2 Cadmium Cd not over 0 01wt or 100wt ppm 3 Mercury Hg not over 0 1wt or 1000wt ppm 4 Hexavalent chromium Cr6 not over 0 1wt or 1000wt pp...

Reviews: