31
12.1.4.
Heating Operation
12.1.4.1. Thermostat control
• Compressor is OFF when Intake Air Temperature - Internal Setting Temperature > +2.0
°
C.
• Compressor is ON after waiting for 3 minutes, if the Intake Air Temperature - Internal Setting Temperature < Compressor OFF
point.
12.1.5.
Automatic Operation
• This mode can be set using remote control and the operation is decided by remote control setting temperature, remote control
operation mode, indoor intake air temperature and outdoor air temperature.
• During operation mode judgment, indoor fan motor (with speed of Lo-) and outdoor fan motor are running for 30 seconds to
detect the indoor intake and outdoor air temperature. The operation mode is decided based on below chart.
Values of T1, T2, and T3 depend on remote control setting temperature, as shown in below table. After the adjustment of T1, T2
and T3 values, the operation mode for that particular environment and remote control setting is judged and performed, based on the
above operation mode chart, every 30 minutes.
There is a temperature shifting on T1, T2 and T3 if the operation mode judged is changed from Cooling/Soft Dry to Heating or vice
versa.
Example of operation mode chart adjustment:
From the above table, if remote control setting temperature = 25,
T1 = 25 + 7 = 32; T2 = 25 - 3 = 22; T3 = 25 - 7 = 18
Remote Control Setting Temperature (
°
C)
T1
T2
T3
16 ~ 18
+10
-3
-5
19 ~ 22
+8
-3
-7
23 ~ 26
+7
-3
-7
27 ~ 30
+6
-3
-8
Operation Mode change from
Temperature shifts (
°
C)
Cooling/Soft Dry
→
Heating
-2
Heating
→
Cooling/Soft Dry
+2
Summary of Contents for CS-E12GKEW
Page 12: ...12 5 Dimensions 5 1 Indoor Unit ...
Page 13: ...13 5 2 Outdoor Unit ...
Page 15: ...15 7 Block Diagram ...
Page 16: ...16 8 Wiring Connection Diagram 8 1 Indoor Unit ...
Page 17: ...17 8 2 Outdoor Unit ...
Page 18: ...18 9 Electronic Circuit Diagram 9 1 Indoor Unit ...
Page 19: ...19 9 2 Outdoor Unit ...
Page 20: ...20 10 Printed Circuit Board 10 1 Indoor Unit 10 1 1 Main Printed Circuit Board ...
Page 21: ...21 10 1 2 Power Printed Circuit Board 10 1 3 Indicator Panel 10 1 4 Patrol ...
Page 22: ...22 10 2 Outdoor Unit 10 2 1 Main Printed Circuit Board ...
Page 55: ...55 16 Technical Data 16 1 Operation Characteristics 16 1 1 CS E7GKEW CU E7GKE ...
Page 56: ...56 ...
Page 57: ...57 ...
Page 58: ...58 ...
Page 59: ...59 16 1 2 CS E9GKEW CU E9GKE ...
Page 60: ...60 ...
Page 61: ...61 ...
Page 62: ...62 ...
Page 63: ...63 16 1 3 CS E12GKEW CU E12GKE ...
Page 64: ...64 ...
Page 65: ...65 ...
Page 66: ...66 ...