8.1.13. Delay OFF Timer Control
Delay OFF timer can be set using remote control, the unit with timer set will stop operate at set time.
8.1.14. Auto Restart Control
1. When the power supply is cut off during the operation of air conditioner, the compressor will re-operate within three to four
minutes (there are 10 patterns between 2 minutes 58 seconds and 3 minutes 52 seconds to be selected randomly) after power
supply resumes.
2. This type of control is not applicable during ON/OFF Timer setting.
8.1.15. Indication Panel
LED
POWER
TIMER
QUIET
POWERFUL
ION
ALLERGEN
BUSTER
Color
Green
Orange
Orange
Orange
Green
Blue
Light ON
Operation ON
Timer Setting ON
Quiet Mode ON
Powerful Mode ON
Ion Mode ON
Operation ON
Light OFF
Operation OFF
Timer Setting OFF
Quiet Mode OFF
Powerful Mode OFF
Ion Mode OFF
Operation OFF
Note:
•
If POWER LED is blinking, the possible operations of the unit are Hot Start, during Deice operation, operation mode
judgment, or delay ON timer sampling.
•
If Timer LED is blinking, there is an abnormality operation occurs.
•
If Ionizer, LED is blinking, there is an abnormality of Ionizer occurs.
8.1.16. Auto Operation Switch
32
CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE