8.1.2.1.4. The frequency changed method
1. After shifting to relative control, (intake-setting) is every 60 seconds, A tap is adjusted according to the domain and frequency
changes relatively to present condition.
2. Intake-setting to other domains by load sudden change (remote control setting, open air introduction, etc.). When it moves, it
has the following renewal of data, an addition and subtraction tap is switched.
3. When the load change was further carried out and suction-setup separates the domain of relative control, it goes to the clause
of initial frequency and operation frequency is determined.
8.1.2.2. The frequency determination method (Heating operation control)
8.1.2.2.1. Basic specification
Intake temperature domain is sent to outdoor. Renewal of data every 60 seconds in outdoor.
Domain directions data (intake-setting) transmitted from indoor determine a changed part of frequency.
Then, a directed changed part changes frequency to the present frequency.
Change of frequency may be 1 tap = 1Hz.
19
CS-E9DKEW CU-E9DKE / CS-E12DKEW CU-E12DKE