Airflow direction (Horizontal, Vertical) Control
o
During any operation mode combines with Patrol operation, airflow direction follows respective operation
mode.
o
During Patrol individual operation if e-ion starts, only Auto Air Swing is allowed. Even if “Air Swing” button is
pressed, no signal is sent to air conditioner, and no change on LCD display.
o
During Patrol individual operation if e-ion stops, Airflow direction louver closed.
LED
display
(Applicable to all models except MKD models)
o
When Patrol operation is selected, Patrol LD illuminates.
o
During Patrol individual operation, only Patrol LED illuminates. When e-ion air purifying operation starts
based on dirtiness level, Power LED, Patrol LED and e-ion LED illuminates.
PATROL
LED
E-ION
TIMER
No Description
BLUE
ORANGE
RED
BLUE
ORANGE
1 When patrol function is not selected
OFF
OFF
OFF
-
-
2 During gas sensor error detection control
OFF
OFF
Blinking
OFF
OFF
3 During E-ion abnormal discharge error
OFF
OFF
OFF
Blinking
OFF
4 During E-ion breakdown error
OFF
OFF
OFF
Blinking
Blinking
5 During Test Mode
OFF
OFF
OFF
OFF
OFF
6 During stop
OFF
OFF
OFF
OFF
OFF
7 2 minutes gas sensor initial stabilization time (Level 0)
ON
OFF
OFF
OFF
OFF
a. Dirtiness level 0*
ON
OFF
OFF
OFF
OFF
b. Dirtiness level 1
OFF
ON
OFF
OFF
OFF
c. Dirtiness level 1*
OFF
ON
OFF
ON
OFF
8
During operation
During patrol
d. Dirtiness level 2
OFF
OFF
ON
ON
OFF
Remote Control Receiving Sound
o
Normal
Operation
Î
Patrol Mode
: Beep
o
Patrol
Mode
Î
Stop
: Long Beep
o
Patrol
Mode
Î
Normal Operation
: Beep
o
Stop
Î
Patrol
: Beep
Timer
Control
o
When ON timer activates when unit stops, previous operation resumes and restored last saved Patrol
operation status.
o
When ON timer activates during any operation, no change and carry on current operation.
o
When OFF timer activates during any operation, all operation stops and the latest Patrol operation status is
saved.
Power Failure Control
o
During Patrol individual operation, if power failure occurs, after power resumes, Patrol individual operation
resumes immediately.
o
During combination operation, if power failure occurs, after power resumes combination operation resume
immediately.
Summary of Contents for CS-C7MKP-7
Page 12: ...12 4 Location of Controls and Components 4 1 Indoor Unit 4 2 Outdoor Unit 4 3 Remote Control ...
Page 13: ...13 5 Dimensions 5 1 Indoor Unit 5 1 1 CS C7MKP 7 CS C9MKP 7 CS C12MKP 7 ...
Page 14: ...14 5 1 2 CS C18MKP 7 CS C24MKP 7 ...
Page 15: ...15 5 2 Outdoor Unit 5 2 1 CU C7MKP 7 CU C9MKP 7 CU C12MKP 7 5 2 2 CU C18MKP 7 ...
Page 16: ...16 5 2 3 CU C24MKP 7 ...
Page 17: ...17 6 Refrigeration Cycle Diagram ...
Page 18: ...18 7 Block Diagram 7 1 1 CS C7MKP 7 CU C7MKP 7 CS C9MKP 7 CU C9MKP 7 CS C12MKP 7 CU C12MKP 7 ...
Page 19: ...19 7 1 2 CS C18MKP 7 CU C18MKP 7 CS C24MKP 7 CU C24MKP 7 ...
Page 24: ...24 9 2 CS C18MKP 7 CU C18MKP 7 ...
Page 25: ...25 9 3 CS C24MKP 7 CU C24MKP 7 ...
Page 27: ...27 10 1 1 2 CS C18MKP 7 CS C24MKP 7 10 1 2 Indicator Printed Circuit Board ...
Page 29: ...29 10 1 6 Human Activity Sensor Printed Circuit Board ...
Page 70: ...70 Figure 3 Figure 4 16 1 1 3 To remove discharge grille Figure 5 ...
Page 72: ...72 Figure 9 Figure 10 ...
Page 74: ...74 16 2 1 3 To remove power electronic controller Figure 13 Figure 14 Figure 15 ...
Page 76: ...76 Figure 19 Figure 20 Figure 21 ...
Page 77: ...77 17 Technical Data 17 1 Thermostat Characteristics Cooling Soft Dry ...