11.2 Indoor Unit
11.2.1
How to Fix Installation Plate
The mounting wall shall be strong and solid enough to prevent if from the vibration.
The center of installation plate should be at more than
c
at right and left of the wall.
The distance from installation plate edge to ceiling should more than
d
.
From installation plate left edge to unit’s left side is
e
.
From installation plate right edge to unit’s right side is
f
.
ƻ
B
: For left side piping, piping connection for liquid should be about
g
from this line.
: For left side piping, piping connection for gas should be about
h
from this line.
1
Mount the installation plate on the wall with 5 screws or more (at least 5 screws).
(If mounting the unit on the concrete wall, consider using anchor bolts.)
o
Always mount the installation plate horizontally by aligning the marking-off line with the thread and using
a level gauge.
2
Drill the piping plate hole with ø70mm hole-core drill.
o
Putting measuring tape at position as shown in the diagram above.
The hole center is obtained by measuring the distance namely 128 mm for left and right hole
respectively. Another method is intersection point of arrow mark extension.
The meeting point of the extension arrow mark is the hole center position.
o
Drill the piping hole at either the right or the left and the hole should be slightly slanting to the outdoor
side. (refer to step 3)
11.2.2
To Drill a Hole in the Wall and
Install a Sleeve of Piping
1
Insert the piping sleeve to the hole.
2
Fix the bushing to the sleeve.
3
Cut the sleeve until it extrudes about 15mm
from the wall.
4
Finish by sealing the sleeve with putty or
caulking compound at the final stage.
Summary of Contents for CS-C7MKP-7
Page 12: ...12 4 Location of Controls and Components 4 1 Indoor Unit 4 2 Outdoor Unit 4 3 Remote Control ...
Page 13: ...13 5 Dimensions 5 1 Indoor Unit 5 1 1 CS C7MKP 7 CS C9MKP 7 CS C12MKP 7 ...
Page 14: ...14 5 1 2 CS C18MKP 7 CS C24MKP 7 ...
Page 15: ...15 5 2 Outdoor Unit 5 2 1 CU C7MKP 7 CU C9MKP 7 CU C12MKP 7 5 2 2 CU C18MKP 7 ...
Page 16: ...16 5 2 3 CU C24MKP 7 ...
Page 17: ...17 6 Refrigeration Cycle Diagram ...
Page 18: ...18 7 Block Diagram 7 1 1 CS C7MKP 7 CU C7MKP 7 CS C9MKP 7 CU C9MKP 7 CS C12MKP 7 CU C12MKP 7 ...
Page 19: ...19 7 1 2 CS C18MKP 7 CU C18MKP 7 CS C24MKP 7 CU C24MKP 7 ...
Page 24: ...24 9 2 CS C18MKP 7 CU C18MKP 7 ...
Page 25: ...25 9 3 CS C24MKP 7 CU C24MKP 7 ...
Page 27: ...27 10 1 1 2 CS C18MKP 7 CS C24MKP 7 10 1 2 Indicator Printed Circuit Board ...
Page 29: ...29 10 1 6 Human Activity Sensor Printed Circuit Board ...
Page 70: ...70 Figure 3 Figure 4 16 1 1 3 To remove discharge grille Figure 5 ...
Page 72: ...72 Figure 9 Figure 10 ...
Page 74: ...74 16 2 1 3 To remove power electronic controller Figure 13 Figure 14 Figure 15 ...
Page 76: ...76 Figure 19 Figure 20 Figure 21 ...
Page 77: ...77 17 Technical Data 17 1 Thermostat Characteristics Cooling Soft Dry ...