Heat Exchanger
Description
Evaporator
Condenser
Tube material
Copper
Copper
Fin material
Aluminium (Pre Coat)
Aluminium
Fin Type
Slit Fin
Louver Fin
Row / Stage
(Plate fin configuration, forced draft)
2 × 14
1 × 18
FPI
21
17
Size (W × H × L)
mm
614 × 294 × 25.4
856 × 457.2 × 22
Refrigerant Control Device
—
Capillary Tube
Refrigeration Oil
(c.c)
—
SUNISO 4GDID or ATMOS M60
(260)
Refrigerant (R-22)
g (oz)
—
645 (22.8)
Thermostat
Electronic Control
—
Protection Device
—
2 Stage Overload Protector
Capillary Tube
Length
mm
—
450
Flow Rate
l/min
—
7.9
Inner Diameter
mm
—
1.2
Air Filter
Material
Style
(c.c)
P.P.
Honeycomb
—
Capacity Control
Capillary Tube
Compressor Capacitor
µF, VAC
—
20 µF, 370VAC
Fan Motor Capacitor
µF, VAC
1.5 µF, 400VAC
1.2 µF, 400VAC
•
Specifications are subject to change without notice for further improvement.
7
CS-C75KE CU-C75KE / CS-C95KE CU-C95KE / CS-C125KE CU-C125KE
Summary of Contents for CS-C125KE
Page 12: ...4 Dimensions 12 S C75KE CU C75KE CS C95KE CU C95KE CS C125KE CU C125KE ...
Page 13: ...13 CS C75KE CU C75KE CS C95KE CU C95KE CS C125KE CU C125KE ...
Page 14: ...5 Refrigeration Cycle Diagram 14 S C75KE CU C75KE CS C95KE CU C95KE CS C125KE CU C125KE ...
Page 15: ...6 Block Diagram 15 CS C75KE CU C75KE CS C95KE CU C95KE CS C125KE CU C125KE ...
Page 20: ...Soft Dry Operation Time Diagram 20 S C75KE CU C75KE CS C95KE CU C95KE CS C125KE CU C125KE ...
Page 73: ...73 CS C75KE CU C75KE CS C95KE CU C95KE CS C125KE CU C125KE ...
Page 84: ...84 S C75KE CU C75KE CS C95KE CU C95KE CS C125KE CU C125KE ...
Page 86: ...22 1 REMOTE CONTROL 86 S C75KE CU C75KE CS C95KE CU C95KE CS C125KE CU C125KE ...
Page 89: ...89 CS C75KE CU C75KE CS C95KE CU C95KE CS C125KE CU C125KE MACC Printed in Malaysia ...