(approximately 150 g each time) while operating the air
conditioner in the cooling cycle; however, one time is not
sufficient, wait approximately 1 minute and then repeat the
procedure. (pumping down-pin)
This is different from previous procedures.
Because you are charging with liquid
refrigerant from the gas side, absolutely do no
attempt to charge with large amount of liquid
refrigerant while operating the air conditioner.
4. Immediately disconnect the charge hose from the 3-way valve’s
service port.
- Stopping partway will allow the refrigerant to be discharged.
- If the system has been charged with liquid refrigerant while
operating the air conditioner, turn off the air conditioner
before disconnecting the hose.
5. Mount the valve stem caps and the service port cap.
- Use torque wrench to tighten the service port cap to a torque
of 18 N.m.
- Be sure to check for gas leakage.
12. Servicing Information
- Inspection points for the Indoor Electronic Controller
1. The Electronic Controller, a signal Receiver and an Indicator (Fig.
2) can be seen by the below steps:
- Remove the 2 caps and 2 screws at the bottom of the front
grille. (Fig. 1)
- Remove the front grille by releasing the 2 hooks at the top of
the front grille. (Fig. 1)
- Remove the control board cover by releasing the 2 tabs at
left, 1 tab on top and 2 more tabs at right side of the control
board cover. (Fig. 1)
2. To remove the Electronic Controller, release the hook that
holding the electronic controller. (Fig. 2)
- Indoor Fan Motor removal procedure:-
1. Remove the control board by:-
67
Summary of Contents for CS-A123KR
Page 13: ...13 ...
Page 14: ...5 Refrigeration Cycle Diagram 14 ...
Page 15: ...6 Block Diagram 15 ...
Page 16: ...7 Wiring Diagram 16 ...
Page 17: ...REMARKS B BLUE BR BROWN BL BLACK W WHITE R RED O ORANGE P PINK Y G YELLOW GREEN 17 ...
Page 29: ...29 ...
Page 32: ...Overload Deicing Time Diagram 32 ...
Page 49: ...3 For the embedded piping 49 ...
Page 50: ... This can be used for left rear piping and left bottom piping also 50 ...
Page 75: ...75 ...
Page 78: ...78 ...
Page 79: ...79 ...
Page 80: ...15 Exploded View 80 ...
Page 89: ...How to use electronic circuit diagram 89 ...
Page 90: ...TIMER TABLE 90 ...
Page 92: ...22 2 PRINT PATTERN INDOOR UNIT PRINTED CIRCUIT BOARD TOP VIEW 92 ...
Page 93: ...22 3 PRINT PATTERN INDOOR UNIT PRINTED CIRCUIT BOARD BOTTOM VIEW 93 ...
Page 94: ... MACC Printed in Malaysia 94 ...