- This control can be omitted by open the circuit of JX1. (Refer
Circuit Diagram)
8.7. Delay ON Timer Control
- When the Delayed ON Timer is set by using the remote control, the
unit will start operate slightly before the set time, so that the room
will reach nearly to the set temperature by the desired time.
- For Cooling and Soft Dry mode, the operation will start 15 minutes
before the set time.
- For Heating mode, the operation will start 30 minutes before the
set time.
- For Automatic mode, the indoor fan will operate at Lo
--
speed for 20
seconds, 30 minutes before the set time to detect the intake air
temperature to determine the operation mode. The operation
indication lamp will blink at this time.
8.8. Remote Control Signal Receiving Sound
- Peep sound (Long) will be heard when:-
- Stopping the Air Conditioner using ON/OFF switch.
- Stopping the Sleep Mode.
- Stopping the Powerful Mode.
- Stopping the Economy Mode.
- Pep sound (Short) will be heard for others.
- To switch off the peep sound, press the “Auto Operation Button”
continuously for 10 seconds or more.
Repeat the above if you want to switch ON the beep sound or
switch OFF the power switch at the indoor unit and switch it ON
again. /
However, if the “Auto Operation Button” have been pressed
the Automatic cooling operation will be activated.
If you do not require this operation, you may change it by using
the remote control.
8.9. Indoor Fan Speed Control
Auto Fan Speed Control
When set to Auto Fan Speed, the fan speed is shifted automatically between Stop to SHi depend
on each operation as shown below.
36
Summary of Contents for CS-A123KR
Page 13: ...13 ...
Page 14: ...5 Refrigeration Cycle Diagram 14 ...
Page 15: ...6 Block Diagram 15 ...
Page 16: ...7 Wiring Diagram 16 ...
Page 17: ...REMARKS B BLUE BR BROWN BL BLACK W WHITE R RED O ORANGE P PINK Y G YELLOW GREEN 17 ...
Page 29: ...29 ...
Page 32: ...Overload Deicing Time Diagram 32 ...
Page 49: ...3 For the embedded piping 49 ...
Page 50: ... This can be used for left rear piping and left bottom piping also 50 ...
Page 75: ...75 ...
Page 78: ...78 ...
Page 79: ...79 ...
Page 80: ...15 Exploded View 80 ...
Page 89: ...How to use electronic circuit diagram 89 ...
Page 90: ...TIMER TABLE 90 ...
Page 92: ...22 2 PRINT PATTERN INDOOR UNIT PRINTED CIRCUIT BOARD TOP VIEW 92 ...
Page 93: ...22 3 PRINT PATTERN INDOOR UNIT PRINTED CIRCUIT BOARD BOTTOM VIEW 93 ...
Page 94: ... MACC Printed in Malaysia 94 ...