Chapter 5. Peripheral Equipment
Section 300-Installation
5-34
DBS Manual - Revised April 2000
DBS-2.3/9.2-300
Single Line Telephone Adaptor
Guidelines
• The Single Line Telephone Adaptor (SLTA, VB-43709) provides an
alternative way of connecting analog DTMF telephones (2500 sets). One
SLTA supports up to 4 Single Line Telephones.
• Each SLT extension requires a digital extension port connection to the
SLTA.
Installation
1. Remove the cover from the SLTA.
2. Remove the cable punch-out plate (Figure 5-20) to make an opening for
the cables coming into the SLTA.
To remove the plate, cut the grooves on either side with diagonal cutters.
Then bend the plate back and forth with needle-nose pliers to remove it.
Figure 5-20. Cable punch-out plate, SLTA
3. Mount the SLTA to the wall (see Figure 5-21).
Note:
Table 5-11 shows the maximum distance the SLTA can be located
from the DBS.