burrs from cut edge. Make flare after inserting the flare nut
(located at valve) onto the copper pipe.
Align center of piping to valves and then tighten with torque
wrench to the specified torque as stated in the table.
CUTTING AND FLARING THE PIPING
1. Please cut using pipe cutter and then remove the burrs.
2. Remove the burrs by using reamer. If burrs is not
removed, gas leakage may be caused.
Turn the piping end down to avoid the metal powder
entering the pipe.
3. Please make flare after inserting the flare nut onto the
copper pipes.
(1) *
*
Connect the manifold gauge to the service port of 3-way
valve.
Measure the pressure.
(2) *
*
Keep it for 5-10 minutes.
Ensure that the pressure indicated on the gauge is the
same as that of measured during the first time.
10.6.4. AIR PURGING OF THE PIPING AND INDOOR UNIT
The remaining air in the Refrigeration cycle which contains moisture may cause malfunction on the compressor.
1. Remove the caps from the 2-way and 3-way valves.
2. Remove the service-port cap from the 3-way valves.
3. To open the valve, turn the valve stem of 2-way valve counter-clockwise approx. 90° and hold it there for ten seconds, then
close it.
4. Check gas-leakage of the connecting portion of the pipings.
For the left pipings, refer to item 4(A).
5. To open 2-way valve again, turn the valve stem counter-clockwise until it stops.
4(A). Checking gas leakage for the left piping.
50
CS-A9DKA CU-A9DKA / CS-A12DKA CU-A12DKA /
Summary of Contents for C
Page 3: ...2 Functions 2 1 Remote Control 3 CS A9DKA CU A9DKA CS A12DKA CU A12DKA ...
Page 5: ...2 3 Outdoor Unit 5 CS A9DKA CU A9DKA CS A12DKA CU A12DKA ...
Page 10: ...4 Dimensions 4 1 Indoor Unit Remote Control 10 CS A9DKA CU A9DKA CS A12DKA CU A12DKA ...
Page 11: ...4 2 Outdoor Unit 4 2 1 CU A9DKA 4 2 2 CU A12DKA 11 CS A9DKA CU A9DKA CS A12DKA CU A12DKA ...
Page 12: ...5 Refrigeration Cycle Diagram 12 CS A9DKA CU A9DKA CS A12DKA CU A12DKA ...
Page 13: ...6 Block Diagram 13 CS A9DKA CU A9DKA CS A12DKA CU A12DKA ...
Page 14: ...14 CS A9DKA CU A9DKA CS A12DKA CU A12DKA ...
Page 15: ...7 Wiring Diagram 15 CS A9DKA CU A9DKA CS A12DKA CU A12DKA ...
Page 16: ...16 CS A9DKA CU A9DKA CS A12DKA CU A12DKA ...
Page 37: ...9 Operating Instructions 37 CS A9DKA CU A9DKA CS A12DKA CU A12DKA ...
Page 38: ...38 CS A9DKA CU A9DKA CS A12DKA CU A12DKA ...
Page 39: ...39 CS A9DKA CU A9DKA CS A12DKA CU A12DKA ...
Page 40: ...40 CS A9DKA CU A9DKA CS A12DKA CU A12DKA ...
Page 41: ...41 CS A9DKA CU A9DKA CS A12DKA CU A12DKA ...
Page 42: ...42 CS A9DKA CU A9DKA CS A12DKA CU A12DKA ...
Page 68: ...14 2 2 CS A12DKA CU A12DKA 68 CS A9DKA CU A9DKA CS A12DKA CU A12DKA ...
Page 79: ...79 CS A9DKA CU A9DKA CS A12DKA CU A12DKA ...
Page 81: ...19 2 Remote Control 81 CS A9DKA CU A9DKA CS A12DKA CU A12DKA ...
Page 83: ...TOP VIEW 83 CS A9DKA CU A9DKA CS A12DKA CU A12DKA ...