ELE-34
IMAGE ROTATION ADJUSTMENT
Notes:
•
Perform the following adjustments after completing
the Screen Voltage Coarse adjustment, High-Voltage,
Focus and X-Ray Protector adjustments.
•
Ensure that CN0RD and CN00R on the S. Correction
PWB are connected to the Deflection Yoke and Main
PWB.
(1) Apply the 1080/60i size adjustment signal to INPUT A
(Terminal Y on the Component/RGB Input Card).
(2) Adjust
D101
of the Service Menu to decrease the image
tilting to no more than
1.5 mm
(
1.5 mm
or less above or
below the middle line). If the reference point which is the
vertical center position on the left of the image (reference
points) is deviated, adjust
DM04
to correct it.
1.10.6 IMAGE ROTATION ADJUSTMENT
Escutcheon
Screen size
Reference
point
1.5 mm
1.5 mm
S. CORRECTION PWB
MAIN PWB
Front side
Front side
(Top surface view of S. CORRECTION PWB)
TP-XR
TP-G
VR505 [CONV_V]
VR504 [CONV_H]
VR502 [H.VOLTAGE]
VR501 [X-RAY]
CN0RD
CN00R
VR505
VR504
VR502
VR501
CN0RD
CN00R
Measuring Instruments
Signal generator (Size adjustment signal)
Card (Slot)
Component/RGB Input Card (Slot 1)
Test Points
Adjustment Points
D101 (Rotation), DM04 (Vertical Position) [Service Menu]