background image

18

ADDITIONAL SYSTEM COMPONENTS

Control Unit BM-ED500

This product is necessary for iris data recognition/enroll-
ment and controlling an electric lock.

Administration Software BM-
ES500E

This product is necessary for administering iris data, ID
data and passwords.

Administration Software
BM-ES500E

Summary of Contents for BMET500 - CAMERA HEAD UNIT

Page 1: ...Before attempting to connect or operate this product please read these instructions carefully and save this manual for future use Model No BM ET500 Iris Camera Operating Instructions ACCEPT REJECT READY ...

Page 2: ...s A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications O...

Page 3: ...ded plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet 10 Protect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the points where they exit from the apparatus 11 Only use attachments accessories specified by the manufacturer 12 Refer all servicing to qualified service personnel Servicing is required whe...

Page 4: ...NTROLS AND THEIR FUNCTIONS 10 INSTALLATIONS AND CONNECTIONS 11 DIMENSIONS OF THE MOUNTING BRACKET 14 ADJUSTMENTS AND MAINTENANCE 15 Adjustment 15 Maintenance 15 RECOGNITION PROCEDURES 16 Iris Recognition 16 ID and password Authorization 17 ADDITIONAL SYSTEM COMPONENTS 18 Control Unit BM ED500 18 Administration Software BM ES500E 18 TROUBLESHOOTING 19 SPECIFICATIONS 21 STANDARD ACCESSORIES 22 ...

Page 5: ...mera for enrollment captures the iris images of both eyes at the same time but the iris data of each eye is enrolled sepa rately 4 Capturing diagnosis is made by the administration software at the time of enrollment 5 Up to 127 gate systems an iris camera and control unit can be connected to the administration PC in the LAN The control unit can also be used as both for enrollment and recognition b...

Page 6: ... with the iris data distributed you will be recognized as an enrolled user The recognition time will be approx 3 seconds approx 2 seconds for capturing and 1 second for recognition 1 1 The recognition time may differ depending on capturing conditions Built in color CCTV camera that captures the user s facial image The iris camera has a built in minisize color camera You can record the facial image...

Page 7: ...d product names appearing in these operating instructions are registered trademarks or trade marks of the company concerned LIMITATION OF LIABILITY This Product is used to recognize an individual person by using Iris data and is not designed to protect against theft or crime independently IN NO EVENT SHALL MATSUSHITA ELECTRIC INDUSTRIAL CO LTD BE LIABLE TO ANY PARTY OR ANY PERSON EXCEPT FOR REPLAC...

Page 8: ...cameras Distribution To transfer enrolled data from the administration PC to control units and to save the data in the control units Enrollment To save a user s iris data associated with the individual information name and ID data etc in the administration PC Iris data is enrolled using the administration software Iris camera The unit Panasonic Iris Camera BM ET500 Iris data Data that are generate...

Page 9: ...y device This unit has no power switch Power is supplied from Control Unit BM ED500 or from an external 24 V DC power supply device Refer to the control unit s operating instructions for how to turn on off the power When you use an external power supply device do the following Turn on the external power supply device before turn ing on Control Unit BM ED500 Turn off the external power supply devic...

Page 10: ...u stand in front of the unit and then inform you that recognition enrollment will start e Built in color CCTV camera This is a color camera for surveillance For example it is used for status confirmation if a recognition has not been successfully executed r Operation indicators These indicators show the operation statuses of the unit The central indicator is lit all the time when power is applied ...

Page 11: ...se power supply 24 V DC BM ET500 For recognition Camera 1 Camera 2 System Instruction Maximum System OK NG BM ET500 For recognition In the case of Wiegand RS 485 use OK NG OK NG For enrollment Administration PC LAN Electric lock Electric lock Door control box Access server Camera 3 BM ET500 BM ED500 POWER ALARM S3 S2 S1 Wiegand or RS 485 The use of the Administration PC was not evaluated by UL The...

Page 12: ...e wall and then attach the sup plied mounting bracket to the anchor Refer to the fig ure in p 14 The anchor bolt should meet the standards shown in the illustration 10 mm 2 5 in or less Wall Mounting bracket 2 mm 2 25 in D 1 2 3 1 Remove the screw Belt Locked 3 Bend the belt and secure it with the screw Unlocked 2 Insert the belt until it hits to the stop 1 2 3 4 5 6 7 8 9 0 ENTER 1 2 3 4 5 CANCEL...

Page 13: ...e that complies with the safety standard Refer to p 21 8 Attach the numeric keyboard Connect the control cable which has been connected to the numeric keyboard Then attach the keyboard with the tamperproof screws Caution Insert the cable into the unit so as to avoid pressure from the keyboard 1 2 3 4 5 CANCEL Screw nut M5 1 Attach the mounting bracket to the wall 2 Remove the numeric keyboard 3 Re...

Page 14: ...14 DIMENSIONS OF THE MOUNTING BRACKET 6 5 22 5 M5 49 45 180 5 186 5 90 47 180 5 174 5 398 26 63 4 φ10 8 124 2 89 4 173 7 99 3 22 R 1 Unit of length mm ...

Page 15: ... are a mirror proximity sensor and two cameras inside the unit The cameras will be used for capturing a face and irises If dust is sticking to the cameras it may cause malfunction Clean the inside of the camera unit as follows 1 Remove the numeric keyboard and the front panel Refer to p 12 and this page 2 Blow dust away from the mirror sensor Camera 1 and Camera 2 by using a blower etc If dust sti...

Page 16: ... status indicators will blink as shown in Figure 1 or 2 When the indicators show Figure 1 status come closer to the unit When the indicators show Figure 2 status go farther from the unit 4 The status indicators will light up in the order shown in the figure When all indicators have lighten up the recognition will be finished 5 When recognition has been successfully executed ACCEPT will light up an...

Page 17: ...ear on the LED indicator For example if you enter a five digit password 5 will light up on the LED indicator If the digit is 10 or more the end number will light up Note If you cancel ID and password authorization and return to iris recognition press CANCEL When the ID and password are matching with the enrolled information ACCEPT will light up and the buzzer will beep briefly When you have mistak...

Page 18: ...M ED500 This product is necessary for iris data recognition enroll ment and controlling an electric lock Administration Software BM ES500E This product is necessary for administering iris data ID data and passwords Administration Software BM ES500E ...

Page 19: ... front panel may have dust or be damaged Remove the dust from the front panel If the panel has been damaged replace it with a new one Refer to p 15 Confirm the connection Refer to p 13 The coaxial cable may not be connected between the unit s coaxial cable connector and the control unit s iris camera connector CAMERA 1 to 3 You may not have opened your eyes widely during capturing You were wearing...

Page 20: ...rd party external power may be off Confirm if the power of the control unit is turned on Refer to the control unit s operating instructions This unit may be disconnected from the control unit Refer to the dealer or service person nel The buzzer level may be too low to be heard The buzzer does not sound Adjust the buzzer level Refer to p 15 ...

Page 21: ...m D 17 in W x 8 3 10 in H x 3 1 10 in D Weight 4 5 kg 10 lbs Input Output CCTV camera output 1 V p p 75 Ω Not investigated UL 294 The external power supply should meet the following specifications and must be a UL Listed access control power limited device Output voltage 24 V DC Output current capacity 0 A to 4 5 A Rated ripple voltage Ripple noise 150 mV p p or less Overcurrent protection Enabled...

Page 22: ...racket 1 pc Screw nut M5 1 pc Tamperproof screw driver tool 1 1 pc Video output cable for the built in color CCTV camera 1 pc Operating instruction sticker 2 1 pc 1 You will use it for installation Keep it in a safe place after use 2 Stick to a viewable area except for the front panel if necessary STANDARD ACCESSORIES ...

Page 23: ...23 ...

Page 24: ...Gabriel Industrial Park 65th Infantry Ave KM 9 5 Carolina P R 00985 809 750 4300 Panasonic Digital Communications Security Company Unit of Matsushita Electric Corporation of America Security Systems Group www panasonic com cctv Executive Office One Panasonic Way 3E 7 Secaucus New Jersey 07094 Zone Office Eastern One Panasonic Way Secaucus NJ 07094 201 348 7303 Central 1707 N Randal Road Elgin IL 6...

Reviews: