background image

10

e

LAN connector

This connector, supporting 10 Base-T/100 Base-TX, is
used for communication with the iris server.

r

Setup cable connector

Setup Cable (an exclusive cable supplied to the admin-
istration software) will be connected between this con-
nector and the serial port of the setup PC.

Note:

Refer to pp. 12 to 15 “SETUP PROCEDURE” for

details.

t

Setup switches

These switches are used for changing the mode of the iris
reader at the time of setup. The assignments are as follows.

Note:

In the factory default setting, all the switches

have been set to OFF.

MAJOR OPERATING CONTROLS AND THEIR FUNCTIONS

qw

Front/Rear tamper detection switch

These switches protect the internal data and setup data
of the iris reader. While the front cover is properly
closed, the front tamper detection switch is pressed
and the iris reader is in the “normal operation” mode.
While the iris reader is attached to the wall, the rear
tamper detection switch is pressed and the iris reader
is in the “normal operation" mode.

If the front cover is opened or the iris reader is removed
from the wall, while the power is on, the front/rear tam-
per detection switch will be activated and the iris reader
enters the "tamper detection" mode. When the switch
becomes activated, the tamper detection buzzer will
work and the iris server will be notified that the iris read-
er has entered the “tamper detection" mode. At the
same time, an alarm signal will be output from the alarm
output2 (tamper detection) terminal on the connection
terminal. (The iris data will be erased from the iris read-
er.) If the tamper detection mode is not cancelled in a
given time, the setup data and operation software will
be erased from the iris reader. In this case, it is neces-
sary to retry the setup, as the iris reader will be set to
the factory default. 

When either of the front/rear tamper detection switch
works, the iris reader enters the “tamper detection”
mode. This mode can be cancelled by setting Setup
switch 3 to ON. (Cancel the “tamper detection” mode
before connections or setup by referring p. 13.) After
setup, when the cover is closed after Setup switch is
set to OFF, the iris reader is automatically reset. Then
the “normal operation” mode will be recovered.

Note:

Mount the iris reader to the flat and firm wall.

Otherwise, the tamper detection switch will not be
pressed and the iris reader cannot enter the “nor-
mal operation” mode.

<Rear Panel>

System Instruction

q

e

r

t

y

Rear tamper detection switch

w

<Rear Panel>

Video surveillance camera

The lens is fixed. Do not touch.

1 2 3 4

ON (Upper side)

Switch

No.

Use

1

2

3

4

Mode change

RS-485 line termi-
nation of card
reader. Set to ON.

Mode change

RS-485 line ter-
mination of
access control
panel. Set
according to the
system configu-
ration.

ON

Line termination
ON

Line termination
ON

OFF

Line termination
OFF

Line termination
OFF

Setting is activated in combination
with Switch 3.

Setting is activated in combination
with Switch 1.

Summary of Contents for BM-ET330E

Page 1: ...Before attempting to connect or operate this product please read these instructions carefully and save this manual for future use REJECT ACCEPT BM ET330 Iris Reader Setup Manual Model No BM ET330E ...

Page 2: ... CONSEQUENTIAL OR EXEMPLARY ARISING OUT OF OR RELATING TO THE PRODUCT 2 PERSONAL INJURY OR ANY DAMAGE CAUSED BY INAPPROPRIATE USE OR NEGLIGENT OPERATION OF THE USER 3 UNAUTHORIZED DISASSEMBLE REPAIR OR MODIFICATION OF THE PRODUCT BY THE USER 4 INCONVENIENCE OR ANY LOSS ARISING OUT OF NON RECOGNITION WHEN IRIS DATA IS ALREADY ENROLLED DUE TO ANY REASON OR CAUSE OTHER THAN ANY FAILURE OR PROBLEM OF ...

Page 3: ...EMARKS 2 PREFACE 4 FEATURES 5 PRECAUTIONS 6 DOCUMENT CONVENTION 8 NOTIFICATION ABOUT THIS DOCUMENT 9 MAJOR OPERATING CONTROLS AND THEIR FUNCTIONS 10 SETUP PROCEDURE 12 Installation of the Setup Software and Setup Procedure 12 Setting Parameters of the Setup Software 14 ...

Page 4: ...ent recognition by one eye capturing is also available 4 Refer to BM ES330E User s Manual supplied with Administration Software BM ES330E for details on available cards and card writers 5 Capturing diagnosis is made by the administration software at the time of enrollment 6 Refer to BM ET330E Operating Instructions for details on card readers 7 The user is recognized with the iris data of either e...

Page 5: ... be approx 10 seconds 2 1 The recognition time may differ depending on capturing conditions 2 The recognition time may differ depending on the traffic of the network or the total number of the enrolled users Built in video surveillance camera The iris reader has a built in minisize colour camera You can record the facial image of a user by connecting this camera and a recorder Using the recognitio...

Page 6: ... to turn on off the power Note While the power is turned off recognition and entrance will NOT be available The third party external power supply must be a UL Listed access control power limited device Replacement part Exchange the following parts for the same type F1 K5D402BK0002 Adopting tamper proof structure Refer to service personnel for relocating or servicing the appliance As the unit has b...

Page 7: ...the body of this appliance That may cause injury When the front panel is damaged refer to the dealer It may affect iris image capturing and cause invalid recognition Avoid placing a receptacle that contains liquid such as water When the liquid falls over the appliance it may cause a fire or electric shock Follow all instructions Otherwise our liability will be limited IN NO EVENT SHALL MATSUSHITA ...

Page 8: ...ion To identify a user by comparing the iris data generated from iris images captured with the data enrolled in the iris database or read out of a card Server certification Certification carried out by the iris server when no corresponding iris data is found in iris readers The iris reader generates iris data from the iris images captured Then the iris data is transferred to the iris server in the...

Page 9: ...on and installation Refer to the manuals supplied to Administration Software BM ES330E CD ROM for details on iris data enrollment and set tings for using the iris reader To install and operate Iris Reader BM ET330E BM ET330E Operating Instructions To use Administration Software BM ES330E BM ES330E User s Manual To setup iris readers BM ET330E Software Installation Guide The screenshots in this doc...

Page 10: ...er detection mode At the same time an alarm signal will be output from the alarm output2 tamper detection terminal on the connection terminal The iris data will be erased from the iris read er If the tamper detection mode is not cancelled in a given time the setup data and operation software will be erased from the iris reader In this case it is neces sary to retry the setup as the iris reader wil...

Page 11: ... the illustration Then close the front cover Tamper detection mode activation cancellation You will cancel the tamper detection mode activated by the front rear tamper detection switch To cancel the tamper detection mode Set Switch 3 to ON When the tamper detection mode is cancelled the buzzer sound will stop and setup becomes available Note Before closing the cover set Switch 3 to OFF If the cove...

Page 12: ...ng the instal lation The product key is written on the CD ROM case The product key is common between the administration soft ware and the setup software Uninstallation When the setup software becomes unnecessary open Add Remove Programs in Control Panel and select BM ET330 setup software The setup software will be unin stalled from the setup PC Setup switches are configured Switch 1 is set to ON T...

Page 13: ...e iris reader and setup PC with the exclusive setup cable supplied to the administration software Attach the round connector of the cable to the setup cable connector of the iris reader and then attach the D sub 9 pin connector of the cable to the serial port of Setup PC When attaching the round connector to the iris reader direct the cable to the left of the connector v Supplying the Power to the...

Page 14: ... prevent the iris reader from booting properly Attaching the Front Cover Attach the front cover to the iris reader Setting Parameters of the Setup Software Menu Bar File F Open O The setup file saved by clicking Save S is opened Only files saved by clicking Save S can be opened Save S The setting is saved into a setup file Note Do not change the file extension Setup data dat Connection C COM Port ...

Page 15: ... is reset Close Button The system setup software is quitted Setting Parameters ET330 ID The ID of iris reader is entered in a decimal num ber 1 to 99999 is available The ID should be same as what is set in the administration software Default setting 1 Network Setting Parameters ET330 IP Address The IP address of iris reader is entered Default setting 192 168 0 3 Server IP Address The IP address of...

Page 16: ...Matsushita Electric Industrial Co Ltd Osaka Japan http www panasonic co jp global 2005 Matsushita Electric Industrial Co Ltd All Rights Reserved N1004 2015 3TR003079CAB Printed in Japan ...