Detaching the Cover

Detach the front cover from the iris camera by removing the
tamperproof screws with the supplied tamperproof screw
driver tool.

Note:

Be sure to shut down the power supply before

detaching the front cover from the iris camera. If the
power is being supplied when the front cover is
detached, the iris camera will enter the "tamper detec-
tion" mode and the buzzer will beep. In case the power
supply cannot be shut down, detach the front cover
from the camera and cancel the "tamper detection"
mode by moving Setup Switch 3 to ON. The buzzer
sound will be stopped.

x

Setup Switch Setting for Setup

Before starting the setup, move Setup Switch 3 to ON to
cancel the "tamper detection" mode. (Set all the other
switches to OFF.)

Tamperproof screws x 2

Approx. 15

 

°

The tamperproof screw holes are 
inclined to the front side approx. 15 

°

 

as you can easily fasten the screws 
while the iris camera is mounted to the wall.

Remove the tamperproof screws with the
supplied tamperproof screw driver tool.

ON (Upper side)

1 2 3 4

c

Connection between the Iris Camera and

Setup PC

Connect the iris camera and setup PC with the exclusive
setup cable supplied to the administration software.

Attach the round connector of the cable to the setup cable
connector of the iris camera, and then attach the D-sub 9
pin connector of the cable to the serial port of Setup PC.
(When attaching the round connector to the iris camera,
direct the cable to the left of the connector.)

v

Supplying the Power to the Iris Camera

Turn on the power of the external power-supply device.
Wait until the guide and result indicator goes out.

b

System Setup

The following is how to boot the setup software.

1. Double-click "BM-ET300 SetupSoftware" in the

folder designated at the time of installation.

"BM-ET300 Login" window will appear.

2. Select the COM port to which the iris camera is

connected, and then enter the password.

• Available characters (Capital and small letters are dis-

tinct.): ABCDEFGHIJKLMNOPQRSTUVWXYZabcdefghij
klmnopqrstuvwxyz0123456789

• 6 to 16 characters are available.
• Default password: BMET300

When the password is accepted, the current setting is
read from the iris camera into the setup software. (The
reading may take a few seconds.)

After the setting is read into the software, the
"Completed." window will appear. When you click on
"OK", the "BM-ET300 setup software" window will
appear. (Refer to p. 13.)

Summary of Contents for BM-ET300

Page 1: ...Before attempting to connect or operate this product please read these instructions carefully and save this manual for future use Model No BM ET300 Iris Camera Setup Manual REJECT ACCEPT BM ET300 ...

Page 2: ...S DOCUMENT 5 TRADEMARKS 5 LIMITATION OF LIABILITY 5 DOCUMENT CONVENTION 6 PRECAUTIONS 7 MAJOR OPERATING CONTROLS AND THEIR FUNCTIONS 9 SETUP PROCEDURE 11 Installation of the Setup Software and Setup Procedure 11 Setting Parameters of the Setup Software 13 ...

Page 3: ...r depending on capturing condi tions 3 The iris camera captures the iris images of both eyes at the same time but the iris data of each eye is enrolled separate ly Enrollment recognition by one eye capturing is also avail able 4 Capturing diagnosis is made by the administration software at the time of enrollment 5 The user is recognized with the iris data of either eye 6 Up to 256 iris cameras enr...

Page 4: ...d in the iris database for certification In this document the certification by the iris server is called server certification The recognition time will be approx 10 seconds 2 1 The recognition time may differ depending on capturing conditions 2 The recognition time may differ depending on the traffic of the network or the total number of the enrolled users Built in video surveillance camera The ir...

Page 5: ... used to recognize an individual person by using Iris data and is not designed to protect against theft or crime independently IN NO EVENT SHALL MATSUSHITA ELECTRIC INDUSTRIAL CO LTD BE LIABLE TO ANY PARTY OR ANY PERSON EXCEPT FOR REPLACEMENT OR REASONABLE MAINTENANCE OF THE PRODUCT FOR THE CASES INCLUDING BUT NOT LIMITED TO BELOW 1 ANY DAMAGE AND LOSS INCLUDING WITHOUT LIMITATION DIRECT OR INDIRE...

Page 6: ...the iris server when no corresponding iris data is found in iris cameras The camera generates iris data from the iris images captured Then the iris data is transferred to the iris server in the LAN which carries out certification The setting in the administration software will determine whether to carry out server certifica tion Setup cable Panasonic BM ET300 Setup Cable Setup PC PC in which the s...

Page 7: ...on off the power Note While the power is turned off recognition and entrance will NOT be available The third party external power supply must be a UL Listed access control power limited device Replacement part Exchange the following parts for the same type F1 K5D402BK0002 Adopting tamper proof structure Refer to service personnel for relocating or servicing the unit As the unit has been designed i...

Page 8: ...ay affect iris image capturing and cause invalid recognition Avoid placing a receptacle that contains liquid such as water When the liquid falls over the product it may cause a fire or electric shock Follow all instructions Otherwise our liability will be limited IN NO EVENT SHALL MATSUSHITA ELECTRIC INDUS TRIAL CO LTD BE LIABLE TO ANY PARTY EXCEPT FOR REPLACEMENT OR REASONABLE MAINTE NANCE OF THE...

Page 9: ...zzer will work and the iris server will be notified that the iris camera has entered the tamper detection mode At the same time an alarm signal will be output from the alarm output2 tamper detection terminal on the connection terminal The iris data will be erased from the iris camera If the tamper detection mode is not cancelled in a given time the setup data and oper ation software will be erased...

Page 10: ...o OFF Tamper detection mode activation cancellation Switch 3 cancels the tamper detection mode acti vated by the front rear tamper detection switch When the tamper detection mode is cancelled the buzzer sound will stop and setup becomes avail able Note Before closing the cover set Switch 3 to OFF If the cover is attached while the switch is set to ON the iris camera cannot work properly y Tamper d...

Page 11: ...l lation The product key is written on the CD ROM case The product key is common between the administration soft ware and the setup software Uninstallation When the setup software becomes unnecessary open Add Remove Programs in Control Panel and select BM ET300 SetupSoftware The setup software will be unin stalled from the setup PC Setup switches are configured Switch 1 is set to ON The normal ope...

Page 12: ...the iris camera and setup PC with the exclusive setup cable supplied to the administration software Attach the round connector of the cable to the setup cable connector of the iris camera and then attach the D sub 9 pin connector of the cable to the serial port of Setup PC When attaching the round connector to the iris camera direct the cable to the left of the connector v Supplying the Power to t...

Page 13: ... mode Set all the other switches to OFF Note The wrong switch setting may prevent the iris camera from booting properly Attaching the Front Cover Attach the front cover to the iris camera Setting Parameters of the Setup Software Notes Items displayed in red and marked with can be con figured only by the setup software They cannot be con figured in the administration software If there is a paramete...

Page 14: ...D The ID of iris camera is entered in a decimal number 1 to 999999999 is available The ID should be same as what is set in the administration software Network Setting Parameters ET300 IP Address The IP address of iris camera is entered Server IP Address The IP address of iris server is entered Gateway IP Address The IP address of gateway of the network to which the iris camera is connected is ente...

Page 15: ... an access control panel and card reader which are connect ed to the iris camera Bit Length The bit length of data which is received from a card reader and which is transferred to an access control panel is set 26 to 128 is available Pulse Width The pulse width of the signal received transferred 30 40 or 50 µs is available Pulse Interval The pulse interval of the signal received transferred 1 0 1 ...

Page 16: ...NM0103 2053 3TR001574CAA Printed in Japan 2003 Matsushita Electric Industrial Co Ltd All rights reserved Matsushita Electric Industrial Co Ltd Osaka Japan http www panasonic co jp global ...

Reviews: