background image

Before operating this product, please read the instructions carefully and save this manual for future use.

Installation Instructions provided

Operating Instructions

<Basics>

4K Integrated Camera

 

Model No. 

AW‑UE70WP

 

Model No. 

AW‑UE70KP

 

Model No. 

AW‑UE70WE

 

Model No. 

AW‑UE70KE

  How the Operating Instructions are configured

 <Basics> 

(this manual)

:

     This <Basics> describes the procedure for basic operation and installation. Before installing this unit, be 

sure to take the time to read through <Basics> to ensure that the unit will be installed correctly. 

This manual <Basics> is also contained as a PDF file on the CD-ROM supplied with the unit.

  <Operations and Settings>:

     The <Operations and Settings> describes how to operate the unit and how to establish its settings. 

The <Operations and Settings> is contained as a PDF file on the CD-ROM supplied with the unit.

 Adobe

®

 Reader

®

 is required to read PDF files.

  Download it from the Adobe Systems website.

 

Die Bedienungsanleitung in Deutsch ist als PDF-Datei in der CD-ROM enthalten.

 

Le mode d’emploi en français est fourni sous forme de fichier PDF sur le CD-ROM.

 

Le istruzioni per l’uso in italiano sono contenute in un file PDF sul CD-ROM.

 

Las instrucciones de funcionamiento en español se encuentran en un archivo PDF del CD-ROM.

 

Документ Инструкция по эксплуатации на русском языке находится в виде PDF-файла на диске CD-ROM.

Operating  Instructions

Installation  Instructions

ENGLISH

SQT1071

F0915TY0

Printed in China

Summary of Contents for AW-UE70KP

Page 1: ...e unit Operations and Settings The Operations and Settings describes how to operate the unit and how to establish its settings The Operations and Settings is contained as a PDF file on the CD ROM supplied with the unit Adobe Reader is required to read PDF files Download it from the Adobe Systems website Die Bedienungsanleitung in Deutsch ist als PDF Datei in der CD ROM enthalten Le mode d emploi e...

Page 2: ...ur lire les fichiers PDF Le télécharger depuis le site Web d Adobe Systems ITALIANO Come aprire i file dei manuali di istruzioni per l uso Se inserendo il CD ROM si apre la schermata di installazione del software interrompere l installazione Aprendo INDEX pdf sul CD ROM viene visualizzato un elenco di manuali di istruzioni per l uso Fare clic sul nome del documento corrispondente al manuale da apr...

Page 3: ...r LGPL V2 1 The software categorized as 3 5 are distributed in the hope that it will be useful but WITHOUT ANY WARRANTY without even the implied warranty of MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE For details refer to the license conditions that appear when the operation described on P 110 of the Operations and Settings is performed At least three 3 years from delivery of this product ...

Page 4: ...ling the unit on a desktop 17 When mounting the unit on a tripod 17 Connections 18 Connections with an HD monitor 18 Connecting a controller AW RP50 AW RP120 IP connection example 19 System example 1 connection with commercially available controller RS 232C daisy chain connection 20 System example 2 connection with commercially available controller RS 422 connection 21 System example 3 serial cont...

Page 5: ...s camera intended for use only with the Mount Bracket enclosed with the unit and Panasonic Direct Ceiling Mount Bracket WV Q105A Use with other apparatus is capable of resulting in instability causing possible injury WARNING Installation should only be performed by qualified installation personnel Improper installation may result in the entire apparatus falling down and causing injury Read this fi...

Page 6: ...ews No of screws Minimum withdrawal strength per screw Approx 1 5 kg 3 30 lb Direct mount supplied accessory Approx 0 23 kg 0 51 lb Hanging Desktop M4 screws supplied accessory 4 196 N 20 kgf Ensure that the mounting strength can support a weight that is at least five times the total mass of the equipment including the camera s main unit WV Q105A optional accessory Approx 0 15 kg 0 33 lb For ceili...

Page 7: ... plug can be plugged into and unplugged from the outlet easily When connecting the AC adaptor to a power outlet on the ceiling or on any other surface where dust may collect wipe off the dust on the power plug at periodic intervals as an anti tracking measure Power switch The unit does not have a power switch The power turns on when its power plug is connected to a power outlet When the power is t...

Page 8: ...ace Refer to the illustration and determine where the unit is to be installed and in which direction it should be mounted Factor in the unit mounting area and include space for the wires extending from its rear panel The asterisk in the illustration marks the position and dimensions of the hole for mounting the mount bracket 66 2 19 32 130 5 1 8 83 5 3 9 32 156 6 1 8 160 6 5 16 78 3 1 16 65 2 9 16...

Page 9: ...ils etc Note 3 Attach the drop prevention wire Pull out the drop prevention wire from the bottom panel of the unit and engage the end with the wire ring through the hole of the mount bracket hook Pull the drop prevention wire and check that it has been attached securely to the hook Pull out the drop prevention wire and engage it with the mount bracket hook End of hook Drop prevention wire Holding ...

Page 10: ...8 kgf cm Main unit mounting screw M3 screw with flat washer spring washer Status display lamp Approx 15 On the camera main unit Holes x3 used to insert the bottom panel On the mount bracket Protrusions x3 used for inserting the camera Hole for checking the positioning Do not do this work while holding the camera head since doing so may result in malfunctioning of the unit Use only the screws suppl...

Page 11: ...ly secure the cable clamp B Fasten the cable clamp Loosely secure the cable clamp in the area shown above Take hold of the strap part slide the cable clamp until it stops moving and then secure it tightly Always disconnect the power supply before connecting or disconnecting cables Connecting or disconnecting cables while the power is turned on may result in malfunctions Note The unit is in the sta...

Page 12: ...revention wire supplied with the WV Q105A to the anchor bolts Mounting the anchor bolts and direct ceiling mount bracket This job is facilitated if the direct ceiling mount bracket is loosely secured to the ceiling panel in one place and the direct ceiling mount bracket and anchor bolts are vertically aligned before the nuts are tightened up 2 First remove the screws which were loosely fastened in...

Page 13: ... approx 2 0 kg 4 41 lb of the camera once it has been installed but also the weight of the L shaped mounting fixture and its supports Use supports that are strong enough to withstand the total weight of the camera once it has been installed and any vibration or other forces to secure the L shaped mounting fixture If the supports are not capable of bearing this weight and forces the unit may become...

Page 14: ...used to secure the unit and mount bracket 4 Push the unit A Turn it approximately 15 degrees away from the installed position B and remove it C Main unit mounting screw M3 screw with flat washer spring washer Approx 15 Do not do this work while holding the camera head since doing so may result in malfunctioning of the unit Note 5 Disengage the drop prevention wire from the mount bracket ...

Page 15: ...he drop prevention wire 4 Mount the unit Align the position of the hole for checking the positioning with the status display lamp Align the holes on the camera main unit used to insert the bottom panel with the protrusions on the mount bracket used for inserting the camera push the camera to the bracket firmly and rotate the main unit by about 15 degrees in the direction of the arrow Secure the un...

Page 16: ...clamp in the area shown above Take hold of the strap part slide the cable clamp until it stops moving and then secure it tightly RS 232C cable LAN cable for RS 422 Coaxial cable for G L IN Always disconnect the power supply before connecting or disconnecting cables Connecting or disconnecting cables while the power is turned on may result in malfunctions Note The unit is in the standby condition w...

Page 17: ...ect Incorrect When mounting the unit on a tripod Attach the tripod to the threaded holes for mounting the camera on the camera s bottom panel Place the tripod on a completely flat and level surface Tighten the screws by hand to mount the tripod securely Use screw for mounting the tripod that satisfy the following standard Screw for mounting tripod 1 4 20UNC ISO1222 6 35 mm 4 5 mm to 6 mm 0 18 to 0...

Page 18: ...one remote control Supplied AC adaptor Note for connecting with an HDMI cable When connecting with an HDMI cable using an HDMI to DVI converter etc be sure to connect the HDMI cable to the connector of the AW UE70 last Connecting the HDMI cable to the connector of the AW UE70 first may result in malfunction 2 1 AW UE70 HDMI cable HDMI to DVI converter etc Switcher Monitor ...

Page 19: ...D 5 4 3 2 1 SV POWER ON BOOT NM 12V IN LAN Pan tilt head camera control signal HDMI SDI signal AW UE70 Remote Camera Controller AW RP50 Remote Camera Controller AW RP120 Supplied AC adaptor External DC power supply Supplied AC adaptor LAN cable Monitor The unit automatically detects the straight cable or crossover cable connected to the LAN connector ...

Page 20: ...details on the service switches see Service switch settings page 42 SW1 Camera address setting standard serial communication Set to AUTO or 1 to 7 Set address numbers so that they do not duplicate each other SW2 SW3 SW4 Communication format Enable standard serial communication ON SW7 Communication baud rate Set to 9600 bps OFF or 38400 bps ON based on your commercially available controller SW8 Com...

Page 21: ...ss setting standard serial communication Set to AUTO or 1 to 7 Set address numbers so that they do not duplicate each other SW2 SW3 SW4 Communication format Enable standard serial communication ON SW7 Communication baud rate Set to 9600 bps OFF or 38400 bps ON based on your commercially available controller SW8 Communication connector Set to RS 422 OFF Configure the following items in the camera m...

Page 22: ... control signal LAN cable straight cable System tally External DC power supply Remote Camera Controller AW RP120 Compact Live Switcher AW HS50 Supplied AC adaptor RS 422 connector The AC adaptor provided with the unit is not shown in the above figure Supplied AC adaptor Make sure the LAN cable connected to the RS 422 connector is a straight cable ...

Page 23: ...itor 1 Monitor 2 Monitor Monitor LAN cable straight cable Remote Camera Controller AW RP50 The AC adaptor provided with the unit is not shown in the above figure Supplied AC adaptor Supplied AC adaptor Personal computer IP video display Wireless access point Mobile terminal IP video display The unit automatically detects the straight cable or crossover cable connected to the LAN connector ...

Page 24: ... available controller AW UE70 Monitor Supplied AC adaptor Remote camera control signal Infrared remote control supplied with commercially available controller Configure the service switches at the bottom of the unit For details on the service switches see Service switch settings page 42 SW6 Infrared output Set to ON System example 6 IP image transmission PoE AW UE70 IP decoder commercially availab...

Page 25: ...th the USB 2 0 specification Connect a mini B connector to the unit The priority mode of the unit needs to be set to USB For details refer to Priority mode tab Priority mode page 67 in Operations and Settings Use communication software optional accessory that is compatible with the USB Video Class and USB Audio Class Note on grounding Ground the unit via the SIGNAL GND ground connector to ground c...

Page 26: ...26 Appearance Unit mm inch 99 3 29 32 77 3 1 32 80 3 5 32 166 6 17 32 183 7 13 64 179 7 3 64 129 5 5 64 48 1 57 64 3 1 8 160 6 5 16 R80 R3 5 32 66 2 19 32 62 2 7 16 ...

Page 27: ...ipment CAUTION To reduce the risk of fire or electric shock and annoying interference use the recommended accessories only CAUTION In order to maintain adequate ventilation do not install or place this unit in a bookcase built in cabinet or any other confined space To prevent risk of electric shock or fire hazard due to overheating ensure that curtains and any other materials do not obstruct the v...

Page 28: ...5 Do not use this apparatus near water 6 Clean only with dry cloth 7 Do not block any ventilation openings Install in accordance with the manufacturer s instructions 8 Do not install near any heat sources such as radiators heat registers stoves or other apparatus including amplifiers that produce heat 9 Do not defeat the safety purpose of the polarized or grounding type plug A polarized plug has t...

Page 29: ...CAUTION The mains plug of the power supply cord shall remain readily operable The AC receptacle mains socket outlet shall be installed near the equipment and shall be easily accessible To completely disconnect this equipment from the AC mains disconnect the power cord plug from the AC receptacle CAUTION Check the installation at least once a year An improper installation could cause the unit to fa...

Page 30: ...e shielded cables which suit the intended purpose of the apparatus Video signal connecting cables Use double shielded coaxial cables which are designed for 75 ohm type high frequency applications for SDI Serial Digital Interface Coaxial cables which are designed for 75 ohm type high frequency applications are recommended for analog video signals Audio signal connecting cables If your apparatus sup...

Page 31: ...ASTA or BSI to BS1362 Check for the ASTA mark or the BSI mark on the body of the fuse If the plug contains a removable fuse cover you must ensure that it is refitted when the fuse is replaced If you lose the fuse cover the plug must not be used until a replacement cover is obtained A replacement fuse cover can be purchased from your local dealer Before use Remove the connector cover How to replace...

Page 32: ... the unit can output Full HD images at up to 60 fps via a network また 4K画質では 最大毎秒30フレームの出力ができま す Changing the Priority Mode enables operation for various applications Required personal computer environment CPU When using 1080 60p 59 94Hz and 1080 50p 50Hz Intel CoreTM i7 3 4 GHz or higher recommended Other than above Intel CoreTM2 Duo 2 4 GHz or higher recommended Memory For Windows 1 GB or higher ...

Page 33: ...rding or edited content and does not guarantee any content if recording or editing does not work properly Likewise the above also applies in a case where any type of repair is made to this unit Network security As you will use the unit connected to a network your attention is called to the following security risks A Leakage or theft of information through the unit B Use of the unit for illegal ope...

Page 34: ...ed rays Black and white images are output in this case The iris will be fixed at open IP video output function featured The unit is equipped with image compression and IP transmission LSI capabilities IP video transmission in SD format is possible The unit is equipped with image compression and IP transmission LSI capabilities 4K画質で最大毎秒30フレー ム FullHD 画質で最大毎秒60フレームの出力ができます Employing the functions o...

Page 35: ...E 1 eliminates need for camera power configurations Configurations for camera s power supply are not necessary when the unit is connected to a network device that supports the PoE standard IEEE802 3at compliant 2 If the AC adaptor and a PoE power supply are connected simultaneously the AC adaptor will have priority Use a category 5e cable or higher when using a PoE power supply The maximum length ...

Page 36: ...Easy IP Setup Software EasyIpSetup exe Mount bracket for installation surface Hanging Desktop 1 page 9 page 15 Main unit mounting screw with flat washer spring washer M3 x 6 mm 1 page 10 page 15 Power cable 1 5 m 4 92 ft for AW UE70WP AW UE70KP 1 for AW UE70WE AW UE70KE 3 This product is equipped with 3 types of AC mains cable Appropriate mains cable must be used in each local area since the other...

Page 37: ... on and manual operations will no longer be possible for some of the items When using the ATW auto tracking white adjustment function under fluorescent lights the white balance may vary In some situations it may be hard to focus at the auto setting In cases like this select the manual setting and focus manually The appropriate brightness may not be obtained when shooting bright objects using the a...

Page 38: ...em parts The optical system parts are the very heart of the camera Under no circumstances must they be touched In the unlikely event that they have become dusty remove the dust by using a camera blower or by wiping them gently with a lens cleaning paper Do not point the camera directly at the sun or a laser beam no matter whether it is turned on or not Taking images of the sun laser beams or other...

Page 39: ...the light sensing directions in which the wireless remote control signals travel Note If the unit is installed near fluorescent lights plasma monitors or other such products or if the unit is exposed to sunlight the effects of the light may make it impossible for the unit to be operated using the wireless remote control Be sure to follow the steps below for installation and use Take steps to ensur...

Page 40: ...r side eStatus display lamp This lights in the following way depending on the status of the unit Orange When the standby status is established Green When the power is on Red When trouble has occurred in the unit Green and blinks twice When a signal matched by the remote control ID has been received from the wireless remote control optional accessory while the power is on Orange and blinks twice Wh...

Page 41: ...d with the unit to this connector to supply the DC 12 V voltage to the unit nCable clamp This is used to hold the cable connection to the DC IN connector and prevent it from becoming disconnected oGround connector Connects to the ground connector on a wall outlet ground bar etc for grounding page 25 pRS 422 connector RS 422 This RS 422 connector RJ 45 is connected when exercising serial control ov...

Page 42: ...meras whose camera address setting switches are set to AUTO cannot coexist with cameras whose switches are set to 1 to 7 Manually setting multiple cameras to the same address will not allow you to control multiple cameras from a single controller simultaneously Notes Service switch settings 1 SW1 to SW3 Camera address setting switches Configure the camera address Set this to AUTO under normal circ...

Page 43: ...operated Once a button has been selected the unit corresponding to the selected button can be operated eSET button If this button is pressed when one of the Manual1 to 3 settings has been selected for Scene on the camera menu and the AWB A memory or AWB B memory has been selected by the white balance adjustment the white balance is automatically adjusted and registered in the selected memory fMODE...

Page 44: ... change will be restored kFOCUS buttons F N These are used to adjust the lens focus manually when the manual setting is established for the lens focus The focus is adjusted in the far using the F button and in the near using the N button lA FOCUS button This is used when automatically adjusting the lens focus mM FOCUS button This is used when manually adjusting the lens focus The FOCUS buttons F a...

Page 45: ...e units using wireless remote controls set a different remote control ID for each control When using one unit set the remote control ID to CAM1 unless the setting needs to be changed Setting procedure Operate the unit s camera menu or the web screen to select a remote control ID CAM1 to CAM4 The camera s CAM1 to CAM4 settings correspond to the CAM1 to CAM4 buttons on the wireless remote control Th...

Page 46: ...f after the network settings have been established another device in the same network has the same IP address the network operations will not be performed properly Set the IP address in such a way that it does not duplicate an existing IP address Do not establish network settings from a multiple number of Easy IP Setup Software programs at the same time for a single camera Similarly do not perform...

Page 47: ... screen of the selected camera is displayed Notes 4 Input the network items and click the Save button When a DHCP server is being used DNS of the Easy IP Setup Software can be set to Auto After the Save button is clicked it takes about 1 minute for the settings in the unit to be completed If the AC adaptor or LAN cable is disconnected before the settings are completed the settings will be canceled...

Page 48: ...matic installation of viewer software is set to On at the time of purchase allowing you to install directly from the unit If a message appears in the web browser s information bar see page 139 in the Operations and Settings If the plug in viewer software ActiveX installation screen continues to appear when switching screens even after it is installed restart the personal computer To uninstall the ...

Page 49: ...ccurred Check the event log Operations and Settings P 109 Cannot operate common to wireless remote control controller Is the power on If the unit s status display lamp is off or if it has lit up orange it means that the unit s power is not being supplied Operations and Settings P 7 Have the limiter functions been set Operations and Settings P 125 to 126 Has the correct unit to be operated been sel...

Page 50: ... and Settings P 91 Are all the cameras in the daisy chain connection turned on P 20 It may be necessary to upgrade the version of the controller so that the controller will support the unit P 36 The unit turns in the opposite direction to the one operated Has the stand alone Desktop installation setting been selected correctly Operations and Settings P 48 P 87 The reversal setting may have been es...

Page 51: ...pgrade the version of the controller so that the controller will support the unit INPUT Power DC 12 V IN PoE IEEE802 3at standard Mic line input Stereo mini jack ø3 5 mm Input impedance Approx 2 kΩ unbalanced Mic input Supported microphones Stereo mic plug in power on off switching via menu Supplied voltage 2 5 V 0 5 V Mic input level 60 dBV 3 dBV 0 dB 1 V Pa 1 kHz Line input Input level 10 dBV 3 ...

Page 52: ... mix Auto Off 6 dB 12 dB 18 dB 24 dB During Auto 0 dB 6 dB 12 dB and 18 dB are available for Auto F Mix Max Gain setting ND filter Auto Through 1 4 4 16 1 64 Auto は Scene の設定が Full Auto のときに選択可能 Electronic shutter speed During Full Auto 59 94 Hz 1 60 to 1 2000 Auto Slow Shutter Off 1 30 to 1 2000 Auto Slow Shutter On 50 Hz 1 50 to 1 2000 Auto Slow Shutter Off 1 25 to 1 2000 Auto Slow Shutter On Du...

Page 53: ...lone Desktop or suspended Hanging To ensure safety the unit must be secured using the mount bracket supplied Camera pan tilt head control IP connecting cable When connecting through a hub LAN cable category 5 or above max 100 m 328 ft When using a PoE hub LAN cable category 5e or above max 100 m 328 ft When a hub is not used LAN cable category 5 or above max 100 m 328 ft AW protocol connecting cab...

Page 54: ...160 60p 2 30p 15p 5p 50p 2 25p 12 5p 5p 1920 1080 1280 720 640 360 320 180 1 The frame rate may be lower than the setting depending on the operating conditions 2 When the image resolution is 3840x2160 640x360 or 320x180 60p or 50p cannot be selected for the frame rate Supported protocol IPv4 TCP IP UDP IP HTTP HTTPS RTSP RTP RTP RTCP FTP DHCP DNS NTP IGMP UPnP ICMP ARP RTSPoverTCP RTSPoverHTTP SSL...

Page 55: ... Easy IP Setup Software 46 Electronic shutter speed 52 F Frame mix 52 G Gain selection 52 Gamma 52 H HDMI cable 11 16 HD monitor 18 I Image stabilization 52 IP address 47 IP decoder 24 L LAN cable 11 16 23 24 41 M MAC address 47 Main unit mounting screw 10 14 15 36 Microphone 25 Mount bracket 8 9 12 15 36 40 N ND filter 52 O Output format 52 P PoE 35 PoE compatible switching hub 24 Power cable 36 ...

Page 56: ...ional legislation By disposing of them correctly you will help to save valuable resources and prevent any potential negative effects on human health and the environment For more information about collection and recycling please contact your local municipality dealer or supplier Penalties may be applicable for incorrect disposal of this waste in accordance with national legislation Note for the bat...

Reviews: