- 7 -
Major operating controls and their functions
ZOOM/FOCUS connector [ZOOM/FOCUS]
This is the standard input connector for the lenses
equipped with a remote control function for zoom focus.
When using a Panasonic pan/tilt head (such as the
AW-PH300A and AW-PH350), use the LENS I/F
connector on the pan/tilt head instead of this connector.
SDI output connector [SDI OUT 1, 2]
Serial digital component signal can be output.
Setting switches
SW NO
OFF
ON
1
EDH
ENABLE
DISABLE
2 SETTING
E350
E860
3 DATA CLIP NORMAL
CLIP
4 NTSC/PAL
NTSC
PAL
1: EDH <ENABLE/DISABLE>
(Factory setting: ENABLE)
An EDH flag is added to SDI output at the ENABLE
setting.
2: Model selection <E350/E860>
(Factory setting: E350)
When the AW-E350, AW-E650, AW-E655 or AW-E750
is used, set this switch at the E350.
When the AW-E860 is used, set this switch at the E860.
3: DATA CLIP <NORMAL/CLIP>
(Factory setting: NORMAL)
At the NORMAL setting, signal input is output at the
same level at which it was input.
At the CLIP setting, signal input at smaller then 0% is
output at 0%, and signal input at more than 100% is
clipped at 100%.
4: NTSC/PAL switching <NTSC/PAL>
(Factory setting: NTSC)
Leave this switch at the factory setting.
AW-PB504N(VQT0H53-2)英.indd 7
2008/09/03 16:34:27