background image

Specifications

15

Synchronous terminal

<REF> terminal

In Genlock mode: Black burst or Tri-level Sync input signals (with loop-through)

 

f

If the loop-through output is not used, provide a 75 

Ω

 termination.

In internal sync mode: Black burst output signal 

×

2

 

f

Connector: BNC

 

f

Same field frequencies as those of the system formats supported

 

f

In the 1080/24PsF and 1080/23.98PsF formats, only Genlock mode supported

 

f

In the 1080/23.98PsF format, black burst signals with 10 Field ID (SMPTE318M standard compliant) or Tri-level Sync 

signals supported

<LTC IN> terminal

This is the LTC (linear time code) input terminal

 

f

Connector: BNC

 

f

Impedance: 1 k

Ω

 

f

Level: 1 to 2 V [p-p]

Video delay time

During Standard mode

1 line (H)

When the frame synchronizer is set to [Off], and the up-converter is set to [Off]

1 frame (F)

When the frame synchronizer is set to on, or the up-converter is set to [On]

 

f

When the signals have passed through PinP, DVE, MultiView, down-converter, or DVI-IN, a maximum delay of 1 frame is 

applied in each case.

During 3G mode

2 lines (H)

When the frame synchronizer is set to [Off]

2 frames (F)

When the frame synchronizer is set to [On]

 

f

Maximum of 2 frame delay is added to each when passed through PinP, DVE, or MultiView.

During 4K mode

1 frame (F)

The frame synchronizer is always on.

 

f

Maximum of 2 frame delay is added to each when passed through PinP, DVE, or MultiView.

 

f

For details on other added delays, refer to “3G mode/4K mode” in Operating Guide (PDF).

Control terminal

<LAN> terminal

Compatible with 100Base-TX and AUTO-MDIX (For IP control)

 

f

Connection cable: LAN cable (CAT5E), max. 100 m (328 ft), STP (Shielded Twisted Pair) cable recommended

 

f

Connector: RJ-45

<PANEL> terminal

Compatible with 100Base-TX and AUTO-MDIX (For Control Panel AV-HS60C1/AV-HS60C2/AV-HS60C4 connection)

 

f

Connection cable (supplied with AV-HS60C1/AV-HS60C2/AV-HS60C4): LAN cable (CAT5E), straight cable, STP 

(Shielded Twisted Pair), 10 m (32.8 ft)

 

f

Connector: RJ-45

<COM1 (M)>/<COM2 (M)>/<COM3 

(M)> terminals

RS-422 control terminal

For master connection for controlling external devices

 

f

Connector: D-sub 9-pin (female) 

×

3, inch screw

<COM4 (M/S)> terminal

RS-422 control terminal

For master/slave connection for controlling external devices

 

f

Connector: D-sub 9-pin (female), inch screw

 

f

Switchable between master connection and slave connection by the menu

<GPI IN> terminal

GPI IN: 18 inputs, general-purpose, photocoupler sensing

ALARM OUT: 1 output, open collector output (negative logic)

 

f

Connector: D-sub 25-pin (female), inch screw

<GPI OUT1>/<GPI OUT2> 

terminals

GPI OUT: 48 outputs, selected from general purpose, tally

Open collector output

 

f

Connector: D-sub 25-pin (female) 

×

2, inch screw

@

@

NOTE

 

t

Use with the same segment is recommended for the devices which are connected to the unit. If the unit is connected to the devices whose segments 
are different, events dependent upon the settings inherent to the network equipment, for instance, may occur. Thoroughly check the connections with 
the devices to which the unit will be connected prior to the start of operation.

Other

Ambient operating temperature

0 °C to 40 °C (32 °F to 104 °F)

Humidity

10% to 90% (no condensation)

Dimensions (W

×

H

×

D)

482 mm

×

132 mm

×

418 mm (18-31/32 inches

×

5-3/16 inches

×

16-15/32 inches) (excluding protrusions)

3RU

Mass

AV-HS60U1: Approx. 12.6 k

]

 (27.8 lbs.) (excluding accessories)

AV-HS60U2: Approx. 13.5 k

]

 (29.7 lbs.) (excluding accessories)

 

r

For AV-HS60U1E/AV-HS60U2E

Inrush current, measured according to European standard EN55103-1, on initial switch-on: 3 A, after a supply interruption of 5 s: 35 A (Each mains 
input)

Summary of Contents for AV-HS60U1E

Page 1: ...n This manual is an excerpted version of the Operating Guide For more information please visit the Panasonic website http pro av panasonic net en manual index html and refer to the Operating Guide PDF Before operating this product please read the instructions carefully and save this manual for future use Please carefully read the Read this first P 2 to 7 of this Manual before use ...

Page 2: ... of the power outlet please consult a qualified electrician WARNING To reduce the risk of fire or electric shock do not expose this equipment to rain or moisture To reduce the risk of fire or electric shock keep this equipment away from all liquids Use and store only in locations which are not exposed to the risk of dripping or splashing liquids and do not place any liquid containers on top of the...

Page 3: ...ant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipme...

Page 4: ...g has two blades and a third grounding prong The wide blade or the third prong are provided for your safety If the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet 10 Protect the power cord form being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus 11 Only use attachments ac...

Page 5: ...nly be performed by qualified personnel For continued protection against risk of fire replace only with the same type 3 15 AH 250 V fuse for F1 F2 WARNING This equipment is compliant with Class A of CISPR 32 In a residential environment this equipment may cause radio interference CAUTION Do not remove panel covers by unscrewing To reduce the risk of electric shock do not remove the covers No user ...

Page 6: ...use need to be replaced please ensure that the replacement fuse has a rating of 13 amps and that it is approved by ASTA or BSI to BS1362 Check for the ASTA mark or the BSI mark on the body of the fuse If the plug contains a removable fuse cover you must ensure that it is refitted when the fuse is replaced If you lose the fuse cover the plug must not be used until a replacement cover is obtained A ...

Page 7: ...ance level The performance level of the apparatus is equivalent to or better than the performance level required by these standards However the apparatus may be adversely affected by interference if it is being used in an EMC environment such as an area where strong electromagnetic fields are generated by the presence of signal transmission towers cellular phones etc In order to minimize the adver...

Page 8: ...How to read this document r r Abbreviations The following abbreviations are used in this document f f The model numbers of the Main Frames AV HS60U1P AV HS60U2P AV HS60U1E AV HS60U2E are described as AV HS60U1 AV HS60U2 f f The model numbers of the Control Panels AV HS60C1P AV HS60C2P AV HS60C1E AV HS60C2E are described as AV HS60C1 AV HS60C2 f f The model numbers of the Control Panels AV HS60C4P ...

Page 9: ...er and electrical ratings of the unit are indicated on its side panel Installation Refer to the Operating Guide of the AV HS6000 series Accessories f f AC cable AV HS60U1P 1 cable AV HS60U2P 2 cables AV HS60U1E 2 cables AV HS60U2E 4 cables f f Rack mounted rear panel support bracket f f Screws for the rack mounted rear panel support bracket 8 screws f f Operating Guide of the AV HS6000 series Exce...

Page 10: ...oes not have the POWER switch for the power supply 2 f f When turning off the power of the redundant power supply model AV HS60U2 set both POWER switches for the power supply 1 and the power supply 2 to OFF NOTE t t When an alarm has occurred stop using the unit immediately and be sure to contact your dealer Rear panel 1 3 4 5 6 7 8 9 10 11 12 14 2 13 1 SDI IN 1 to SDI IN 32 terminals connector BN...

Page 11: ...input ports GPI IN that control the unit externally and an alarm output port ALARM OUT 11 GPI OUT1 GPI OUT2 terminals connector D sub 25 pin female 2 inch screw signal GPI OUT Equipped with 48 output ports GPI OUT that output tallies and status information from the unit 12 SIGNAL GND terminal signal SG Connects to the ground of the system 13 F1 F2 terminals Fuse 14 AC IN 1 AC IN 2 terminals signal...

Page 12: ...4 4 4 6 4 5 4 7 4 9 4 8 OP STILL1 BUS SHFT 4 SDI IN3 3 SDI IN2 2 SDI IN1 1 Black 12 11 10 SDI IN9 9 SDI IN8 SDI IN11 SDI IN10 8 SDI IN7 7 SDI IN6 6 SDI IN5 5 SDI IN4 Red Red Blue Fig 2 Fig 3 1 Press the button blinking in red Fig 1 Update of the firmware is started f f Status when the firmware of the Control Panel is being updated Fig 2 Eight buttons out of the PGM A bus crosspoint buttons in the ...

Page 13: ...cable is used During 3G mode 16 lines f f Connector BNC 16 only the odd numbered terminals can be used f f The even numbered terminals SDI IN 2 SDI IN 4 SDI IN 32 cannot be used f f SDI IN 25 SDI IN 27 SDI IN 29 and SDI IN 31 terminals are equipped with color correctors During 4K mode 4K signal eight lines f f Connector BNC 32 constructs one line of 4K signal with four terminals f f Can use the 4K...

Page 14: ...ut from the SDI OUT 13 and SDI OUT 15 terminals f f SDI OUT 13 and SDI OUT 15 terminals are equipped with color correctors The same color corrector setting is also applied to SDI OUT 14 and SDI OUT 16 terminals f f ME1PGM ME1PVW ME1CLN ME1KEYPVW ME2PGM ME2PVW ME2CLN DSKPGM1 DSKPGM2 DSKPVW1 DSKPVW2 DSK1CLN DSK2CLN SEL KEYPVW MV1 to MV2 and AUX1 to AUX8 can be assigned During 4K mode 4K signal outpu...

Page 15: ...or RJ 45 PANEL terminal Compatible with 100Base TX and AUTO MDIX For Control Panel AV HS60C1 AV HS60C2 AV HS60C4 connection f f Connection cable supplied with AV HS60C1 AV HS60C2 AV HS60C4 LAN cable CAT5E straight cable STP Shielded Twisted Pair 10 m 32 8 ft f f Connector RJ 45 COM1 M COM2 M COM3 M terminals RS 422 control terminal For master connection for controlling external devices f f Connect...

Page 16: ... them to applicable collection points in accordance with your national legislation By disposing of them correctly you will help to save valuable resources and prevent any potential negative effects on human health and the environment For more information about collection and recycling please contact your local municipality dealer or supplier Penalties may be applicable for incorrect disposal of th...

Reviews: