49
Aquarea air / water heat pump – design handbook 07 / 2014
Products, functions and technical data
Accessories
Aquarea Heat Pump Slimline
Basic Appliance
1
Hot water draw off (22 mm) compression
2
Temperature & pressure relief valve 92 – 95°/ 6 bar
3
Hot water secondary return 22 mm (210 litre model only)
4
Immersion heater 1¾” BSP 3 kW
5
22 mm cold supply
6
Primary return (28 mm)
7
Primary flow (28 mm)
8
Dual control / Overheat stat
9
HP control thermostat
Part G3 loose components supplied in a separate box
A
Combination inlet group incorporating pressure reducing valve, strainer,
check valve, balance cold take off point, expansion relief valve and
expansion vessel connection points.
B
Potable expansion vessels c/w flexible hose and wall bracket
C
Tundish
D
Dual control thermostat and combined overheat thermostat (× 2)
E
Three port motorised valve for primary circuit
F
Wiring junction box for primary system
1
8
5
4
9
6
3
7
2
Aquarea HP Slimline
Typical arrangement of component
kit shown fitted to the appliance for
clarity.
Pipework to be supplied
and fitted by installer.