122
Aquarea air / water heat pump – design handbook 07 / 2014
Appendix
Heating capacity in relation to supply water and outside temperature
Aquarea LT
Outside temperature
Supply water temperature
Models
30
35
40
45
50
55
9 kW (three phase)
WH-MDF09C3E8
WH-MDC09C3E8
-15
8 .7
8 .0
8 .0
7 .8
7 .2
6 .7
-7
9 .4
9 .1
8 .9
8 .7
8 .0
7 .1
2
9 .3
9 .0
9 .0
9 .0
8 .3
8 .8
7
9 .0
9 .2
9 .0
9 .0
9 .0
8 .0
25
9 .0
9 .0
8 .7
8 .5
8 .3
8 .1
30
35
40
45
50
55
12 kW (three phase)
WH-MDF12C9E8
WH-MDC12C9E8
-15
9 .3
8 .9
8 .5
8 .1
7 .5
7 .0
-7
10 .4
11 .1
9 .6
9 .2
8 .7
8 .2
2
11 .8
11 .9
11 .0
10 .6
9 .8
9 .1
7
12 .0
12 .2
12 .0
12 .0
12 .0
12 .0
25
12 .0
12 .0
11 .8
11 .7
11 .5
11 .4
30
35
40
45
50
55
14 kW (three phase)
WH-MDF14C9E8
WH-MDC14C9E8
-15
9 .9
9 .8
9 .0
8 .6
7 .9
7 .3
-7
11 .1
11 .8
10 .2
9 .8
9 .1
8 .5
2
12 .9
12 .7
11 .9
11 .4
10 .4
9 .5
7
14 .0
14 .1
14 .0
14 .0
13 .6
13 .3
25
14 .0
14 .0
14 .0
14 .0
14 .0
14 .0
30
35
40
45
50
55
16 kW (three phase)
WH-MDF16C9E8
WH-MDC16C9E8
-15
10 .6
10 .1
10 .0
9 .7
8 .8
7 .9
-7
11 .9
11 .4
10 .8
10 .3
9 .6
7 .8
2
13 .5
12 .7
12 .4
11 .9
10 .8
9 .8
7
16 .0
15 .8
16 .0
15 .9
15 .2
14 .3
25
16 .0
16 .0
16 .0
16 .0
16 .0
15 .9
Heating capacity [kW] of individual models of the
monobloc system
for different supply water and outside temperatures [°C].