background image

F0802Y3093 

@

Printed in Japan
VQT0A37-3

PANASONIC BROADCAST & TELEVISION SYSTEMS COMPANY

UNIT COMPANY OF MATSUSHITA ELECTRIC CORPORATION OF AMERICA

Executive Office:

One Panasonic Way 4E-7, Secaucus, NJ 07094   (201) 348-7000

EASTERN ZONE: 

One Panasonic Way 4E-7, Secaucus, NJ 07094   (201) 348-7621

Southeast Region:

1225 Northbrook Parkway, Ste 1-160, Suwanee, GA 30024   (770) 338-6835

Central Region:

1707 N Randall Road E1-C-1, Elgin, IL 60123   (847) 468-5200

WESTERN ZONE: 

3330 Cahuenga Blvd W., Los Angeles, CA 90068   (323) 436-3500

Government Marketing Department:

52 West Gude Drive, Rockville, MD 20850   (301) 738-3840

Broadcast PARTS INFORMATION & ORDERING:

9:00 a.m. – 5:00 p.m. (EST) (800) 334-4881/24 Hr. Fax (800) 334-4880
Emergency after hour parts orders (800) 334-4881

TECHNICAL SUPPORT:

Emergency 24 Hour Service (800) 222-0741

Panasonic Canada Inc.

5770 Ambler Drive, Mississauga, Ontario L4W 2T3   (905) 624-5010

Panasonic de Mexico S.A. de C.V.

Av angel Urraza Num. 1209 Col. de Valle 03100 Mexico, D.F. (52) 1 951 2127

Panasonic Sales Company
Division of Matsushita Electric of Puerto Rico Inc.

San Gabriel Industrial Park, 65th Infantry Ave., Km. 9.5, Carolina, Puerto Rico 00630   (787) 750-4300

P

Summary of Contents for AK-HCU931

Page 1: ...5A FUSE LEVEL PGM PGM 1 SYSTEM PRIVATE MIC ON PTT OFF OFF PGM 2 250V 5A SHORT ALARM Camera Control Unit P U S H Model AK HCU931P Before attempting to connect operate or adjust this product please read these instructions completely Camera Control Unit ...

Page 2: ...ow the attached installation instructions and do not make any unautho rized modifications This equipment has been tested and found to comply with the limits for a class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful inter ference when the equipment is operated in a commer cial environment This equipment generates use...

Page 3: ...m k6 BNC termination resistor k1 Communication connector k1 Power cord k1 Operating precautions O Handle the unit carefully Dropping the unit or subjecting it to strong impact may cause malfunctioning and or accidents O Operate the unit within a temperature range of 32oF to 104oF 0oC to i40oC Operation in locations below 32oF or above 104oF may adversely affect the internal parts O Be absolutely s...

Page 4: ...ave the unit repaired 8 Camera cable open alarm LED CABLE OPEN Lighted The cable between the CCU and camera has been disconnected Off Normal 9 Camera cable short circuit alarm LED CABLE SHORT Lighted The cable between the CCU and the camera has short circuited Off Normal TALLY indicator CALL switch TALLY CALL This indicator lights when the R G tally signal is input It is also a CALL switch for cal...

Page 5: ... for outputting the D1 format video signals of the SDTV serial digital interface There are 3 connectors BNC G Analog return video 1 2 input connectors ANALOG RET 1 2 These connectors BNC are for inputting the SD analog return video signals H PROMPT IN connectors PROMPT1 2 These are the prompter signal input connectors BNC Input SDTV composite video signals as the prompter sig nals I SDTV waveform ...

Page 6: ...tion M SDTV analog SYNC output connector SDTV ANALOG SYNC The SDTV analog sync signal of the camera is output from this connector BNC Its amplitude is 2 Vp p 75h termination N HDTV genlock input connectors HD REF These are the HDTV genlock input connectors BNC The bridging connection between the two connectors enables one to be used for input purposes and the other for output purposes Input the HD...

Page 7: ...e RTS system from this con nector The microphone level is j4 dBm 200h RTS output connector HA16RD 3P made by Hirose Pin No Function Shield Polarity i j Signal flow CCU SYSTEM CCU SYSTEM 1 Hot 2 Cold 3 Camera control unit rear panel A B C P Q R S T U V W X Y Z L M N O 1 2 P U S H HD RET1 SDI INPUT SDI OUTPUT RET2 RET3 RET4 OUT1 OUT2 OUT3 OUT4 PM Y G Pb B Pr R PM HD OUTPUT SD RET1 SDI INPUT SDI OUTP...

Page 8: ...w when SEQ is selected by moni tor selector switch on ROP or MSU for parade display 2 TTL level low THREE LINE OR FIELD Open TTL level low when ENC SEQ is selected by monitor selector switch on ROP or MSU 3 N C Not connected Not connected 4 CH1 Open TTL level low when G or SEQ is selected by monitor selector switch on ROP or MSU 5 CH2 Open TTL level low when B or SEQ is selected by monitor selecto...

Page 9: ...L AUDIO TRUNK WFM CONTROL AUX ROP CSU MSU ALARM GND MIC OUT WFM2 PM1 PM2 VBS1 VBS2 HD HD REF SD SD OUTPUT INPUT 1 2 SYNC OUTPUT SD REF AC IN F E G H I J K D Y ROP connector The remote operation panel ROP is connected to this connector ROP connector HR10A 10R 10S Pin No Function ROP CONT H Polarity i Signal flow CCU ROP 1 ROP CONT C j CCU ROP 2 ROP DATA H i ROP CCU 3 ROP DATA C j ROP CCU 4 POW REM ...

Page 10: ...tor are shorted If power is supplied to the CCU and any of the DC power supplies inside the CCU fails to output the supply voltage it means that pins 1 and 2 of this connector are shorted Alarm connector RM 12BRB 4PH made by Hirose Pin No Function POWER ALARM H 1 POWER ALARM L 2 FAN ALARM H 3 FAN ALARM L 4 1 Turn off the power of CCU 2 Turn the knobs and remove the front panel 3 Switch the SW281 M...

Page 11: ...D sync signal input black burst BB MSU connector panel MSU cable ROP connector panel ROP cable Main line SD outputs VBS k2 SD analog VBS RET video input k2 The HD output unit AK HHD931P is an optional accessory SD digital D1 RET video inputs k4 Video Video Control Tally inputs R G INCOM input out put ENG PROD PGM inputs PGM1 PGM2 SD WFM SD picture monitor Handy camera AK HC931P Handy camera build ...

Page 12: ...nal switch SD sync signal input black burst BB Decide on a valid REF input signal using the internal switch MSU connector panel MSU cable ROP connector panel ROP cable SYNC output for HD monitor system Main line SD outputs VBSk2 SD analog VBS RET video inputs k2 Install the HD output unit AK HHD931P which is an optional accessory SD digital D1 RET video inputs k4 Video Video Control Tally inputs R...

Page 13: ...ol Unit P U S H P U S H HD RET1 SDI INPUT SDI OUTPUT RET2 RET3 RET4 OUT1 OUT2 OUT3 OUT4 PM Y G Pb B Pr R PM HD OUTPUT SD RET1 SDI INPUT SDI OUTPUT RET2 RET1 RET2 PROMPT RET3 RET4 OUT1 OUT2 OUT3 OUT4 SD COMMUNICATION WFM1 IN RTS OUT CH 1 CH 2 DIGITAL AUDIO TRUNK WFM CONTROL AUX ROP CSU MSU ALARM GND MIC OUT WFM2 PM1 PM2 VBS1 VBS2 HD HD REF SD SD OUTPUT INPUT 1 2 SYNC OUTPUT SD REF AC IN ...

Page 14: ... audio output MIC 1 2 Switch functions Refer to Parts and their functions page 4 Operating temperature range 0 to i40 C i32 to 104 F Storage temperature range j20 to i60 C j4 to 140 F Operating ambient humidity Less than 85 Weight Approx 20 0 kg 44 lbs Dimensions WkHkD 420k132k459 mm excluding protrusions 16 9 16k5 1 4k16 9 16 inches Power supply AC 120 V Power consumption 80 W when unit is operat...

Page 15: ...15 ...

Page 16: ...W Los Angeles CA 90068 323 436 3500 Government Marketing Department 52 West Gude Drive Rockville MD 20850 301 738 3840 Broadcast PARTS INFORMATION ORDERING 9 00 a m 5 00 p m EST 800 334 4881 24 Hr Fax 800 334 4880 Emergency after hour parts orders 800 334 4881 TECHNICAL SUPPORT Emergency 24 Hour Service 800 222 0741 Panasonic Canada Inc 5770 Ambler Drive Mississauga Ontario L4W 2T3 905 624 5010 Pa...

Reviews: