Items supporting RS-232C
Additional set-up menu items
<INTERFACE>
Description of setting
Item
Setting
No.
Superimposed display
These settings are for selecting whether the RS-232C
connector is to function when the REMOTE/LOCAL
switch is set to REMOTE.
0: Connector does not function.
1: Connector functions.
No.
Superimposed display
204
RS232C SEL
0000
OFF
0001
ON
0000
0001
0002
0003
0004
0005
0000
0001
0000
0001
300
600
1200
2400
4800
9600
7
8
1
2
These settings are for selecting the RS232C
communication speed (baud rate).
BAUD RATE
205
206
DATA LENGTH
207
STOP BIT
208
PARITY
209
RETURN ACK
These settings are for selecting the RS-232C data
length.
(Unit: bit)
These settings are for selecting the RS-232C stop bit
length.
(Unit: bit)
These settings are for selecting the none, odd or even
for the RS-232C parity bit.
0: Parity bit is not used.
1: An odd number of bits is used for the parity system.
2: An even number of bits is used for the parity system.
0000
NON
0001
ODE
0002
EVEN
These settings are for selecting whether the ACK code
is to be returned when a command is received from RS-
232C.
0: ACK code is not returned.
1: ACK code is returned.
0000
OFF
0001
ON
The underlining indicates the factory settings.
RS-232C interface
1. Introduction
1) The VTR can be operated by commands when the RS-232C interface is used.
(See command table on pages E-10
E-12.)
2) Conditions for acknowledging commands from RS-232C interface
The front panel REMOTE/LOCAL switch must be at REMOTE.
The set-up menu item No.204 “RS232C SEL” must be ON.
If the above conditions are not met, [ACK] + [STX]ER001[ETX] is returned to the external unit.
Whether the [ACK] code is returned depends on the setting which has been selected for set-up menu
item No.209 “RETURN ACK.”
– E-4 –