background image

 

AJ8R

 

 8

 

DIMENSIONS

 

Double pole (ON-OFF)

24

13

56

Suitable connector: CT connector

32

1.260

16

°

±

4

°

8.6

.339

16

.630

0.8

.031

13.5

.531

10.6

.417

4.4

.173

2

.079

1.75

φ

.069

φ

15

.591

29.8

±

0.3

1.173

±

.012

6.35

.250

19.7

.776

25

.984

22

.866

+

0

0.2

+

0

.008

18.3

.720

(11.3)

(.445)

21.7

±

0.25

.854

±

.010

Edge

The opening radius from when
the panel was processed should
be on the front side of the panel

Opening radius

 

Remarks: 1. The external dimensions and mounting dimensions for the single pole, single throw 

type and the single pole, double throw type are the same as those for the double pole, 
single throw type indicated above.

2. The figures show the double pole, single throw (ON-OFF) type as an example. 

The contact terminals are 1, 2, 3, and 4.
In the case of the single pole, single throw (ON-OFF) type, the contact terminals are 1 
and 2.
In the case of the single pole, double throw (ON-ON) type, the contact terminals are 
1, 2, and 4.
There are no other terminals.
Refer to the internal wiring diagram.

3. The coil is a polarized coil; coil terminal 5 is positive and coil terminal 6 is negative.

 

Wiring diagram(Bottom view)

Single pole (ON-OFF)

Single pole (ON-ON)

Double pole (ON-OFF)

ON (set): 1-2

2

56

1

Reset:
Set:

1-4 closed
1-2 closed

24

56

1

2

56

4

13

ON (set): 1-2 closed

3-4 closed

 

Diagram of recommended locations for 
panel mounting holes

 

Remark: Contact us if you are considering 

using a panel of other than the rec-
ommended size and shape.

Panel thickness

X

Y

1 to less than 1.8

.039 to .071

30.4

1.197

22.0

.866

1.8 to 2.3

.071 to .091

31.1

1.224

22.0

.866

X

Y

R Max. 01

 

+0

–0.1

+0.1

–0

+0

–.004

+.004

–0

+0

–0.1

+0.1

–0

+0

–.004

+.004

–0

Summary of Contents for AJ8R

Page 1: ...h AMP s CT connectors which are widely used for wiring connections in OA equipment making it possible to achieve greater effi ciency in wiring work Receptacle for AMP s CT connector receptacle socket 4 Prolonged electrical service life Coil operation provides an electrical life of at least 50 000 switching operations 5 Assures excellent ability to with stand inrush current when used to turn a powe...

Page 2: ...tage Flange color Dark gray Flange color Black Single pole ON OFF 5V DC AJ8R1001ZC AJ8R1001ZBC 12V DC AJ8R1003ZC AJ8R1003ZBC 24V DC AJ8R1004ZC AJ8R1004ZBC ON ON 5V DC AJ8R5001ZC AJ8R5001ZBC 12V DC AJ8R5003ZC AJ8R5003ZBC 24V DC AJ8R5004ZC AJ8R5004ZBC Double pole ON OFF 5V DC AJ8R2001ZC AJ8R2001ZBC 12V DC AJ8R2003ZC AJ8R2003ZBC 24V DC AJ8R2004ZC AJ8R2004ZBC 3 With O indications on actuators Actuator...

Page 3: ... rated load Min 5 104 at 7 cpm 5A 125V AC resistive load Mechanical life Min 5 104 at 20 cpm Initial contact resistance By voltage drop at 1A 2 to 4V DC Max 100mΩ Initial insulation resistance Min 100mΩ at 500V DC measured by insulation resistive meter Initial breakdown voltage Between contacts 2 000 Vrms Between coil and contact 4 000 Vrms Ambient temperature 0 C to 60 C 32 F to 140 F Not freezin...

Page 4: ...terminals are 1 2 3 and 4 In the case of the single pole single throw ON OFF type the contact terminals are 1 and 2 In the case of the single pole double throw ON ON type the contact terminals are 1 2 and 4 There are no other terminals Refer to the internal wiring diagram 3 The coil is a polarized coil coil terminal 5 is positive and coil terminal 6 is negative Wiring diagram Bottom view Single po...

Page 5: ...t stress from the connecting wires 8 Take care not to drop the product as it may impair performance 9 Resistance to chemicals To clean the switch unit use a neutral detergent diluted with water Do not use acidic or alkaline solvents as they may damage the switch Furthermore be careful not to get any of the detergent solution inside of the switch while cleaning it 10 This product is not hermeticall...

Reviews: