60
Error messages
(continued)
If “T&S&M” is selected in the menu No. 008 DISPLAY SEL, a message appears in the modedisplay whenever a warning or
error occurs. When multiple events occur, the event with the highest priority is displayed.
UMID information display
This is displayed when UMID information is present on the input signal in EE mode.
This lamp lights during tape playback when UMID information has been recorded on the tape. “NO-INFO” is displayed when
there is no UMID information.
Priority
Display
Description
High
Low
Error messages
(See error message table)
When an operational malfunction has occurred in the unit, the error number flashes and the
error message is indicated on the counter display.
INT SG
When SG has been selected as the input signal by the INPUT SELECT button, the “INT SG”
display will appear for the first two seconds at the start of operation (EE mode) when the REC
button is pressed.
NO INPUT
If there are no input signals--with the exception of the analog audio signals-- supplied to the
connectors selected by the INPUT SELECT button, the “NO INPUT” display will appear for the
first two seconds at the start of operation (EE mode) when the REC button is pressed.
Warning messages
(See error message table)
When a warning occurs in this unit, the error number and warning message are indicated on the
counter display. When multiple warnings occur, the warning with the highest priority is
displayed.
Display
Description
MATNO
Material number
COPY
Instance number (No. of copies)
OWNR
Country, organization, user
POS
Reception status from GPS satellites when recording spatial coordinates
(height above sea level, longitude and latitude):
HOLD:
No reception from any satellite
2D:
Reception possible, but number of satellites is insufficient. Height
above sea level will not be accurate.
3D:
Good reception
DATE
Date
TIME
UTC (Coordinated Universal Time) and time difference with UTC