ELE-23
13. Adjust the slider so that the high and low period of the
signal of TP6 appear in the high or low period of the
signal of TP2 as sown figure.
14. Click
“>>”
.
15. Connect a scope to
TP1
and
TP2
(Trigger) and adjust
“VAL”
of volt/div. of oscilloscope so that the level of
envelope becomes 5 unit (div.) of scale of the
oscilloscope.
16. Click
“OK”
.
17. Adjust the slider so that the level of envelope becomes
2 unit (div.) of scale of the oscilloscope.
18. Click
“>>”
.
19. Adjust the slider so that the level of envelope becomes
2 unit (div.) of scale of the oscilloscope.
20. Click
“>>”
.
21. Connect a scope to
TP6
and
TP2
(Trigger).
22. Adjust the slider so that the high and low period of the
signal of TP6 appear in the high or low period of the
signal of TP2 as sown figure.
23. Click
“>>”
.
24. Adjust the slider so that the high and low period of the
signal of TP6 appear in the high or low period of the
signal of TP2 as sown figure.
25. Click
“>>”
.
4-7. Head Clogging
Detection Level Adj. R-ch
BOARD
HBUFF Board
TP
TP1, TP2, TP6
ADJ.
EVR
MODE
REC
TAPE
DVCPRO BLANK
M. EQ.
Oscilloscope
SPEC.
See Figure
1. Set
the
“OUTPUT”
switch to
“BARS”
.
2. Click the
“8. Head Clogging Detection Level
Adjustment R”
of the VTR adjustment software.
3. Record the color bar signal.
4. Connect a scope to
TP1
and
TP2
(Trigger) and adjust
“VAL”
of volt/div. of oscilloscope so that the level of
envelope becomes 5 unit (div.) of scale of the
oscilloscope.
5. Click
“OK”
.
6. Adjust the slider so that the level of envelope becomes
2 unit (div.) of scale of the oscilloscope.
7. Click
“>>”
.
8. Adjust the slider so that the level of envelope becomes
2 unit (div.) of scale of the oscilloscope.
9. Click
“>>”
.
10. Connect a scope to
TP6
and
TP2
(Trigger).
11. Adjust the slider so that the high and low period of the
signal of TP6 appear in the high or low period of the
signal of TP2 as sown figure in 4-6.
12. Click
“>>”
.
13. Adjust the slider so that the high and low period of the
signal of TP6 appear in the high or low period of the
signal of TP2 as sown figure in 4-6.
14. Click
“>>”
.
15. Connect a scope to
TP1
and
TP2
(Trigger) and adjust
“VAL”
of volt/div. of oscilloscope so that the level of
envelope becomes 5 unit (div.) of scale of the
oscilloscope.
16. Click
“OK”
.
17. Adjust the slider so that the level of envelope becomes
2 unit (div.) of scale of the oscilloscope.
18. Click
“>>”
.
19. Adjust the slider so that the level of envelope becomes
2 unit (div.) of scale of the oscilloscope.
20. Click
“>>”
.
21. Connect a scope to
TP6
and
TP2
(Trigger).
22. Adjust the slider so that the high and low period of the
signal of TP6 appear in the high or low period of the
signal of TP2 as sown figure in 4-6.
23. Click
“>>”
.
24. Adjust the slider so that the high and low period of the
signal of TP6 appear in the high or low period of the
signal of TP2 as sown figure in 4-6.
25. Click
“>>”
.
4-8. Head Clogging
Detection Level Confirmation
BOARD
HBUFF Board
TP
-
ADJ.
EVR
MODE
REC
TAPE
DVCPRO BLANK
M. EQ.
-
SPEC.
WARNING CONDITION
1. Set
the
“OUTPUT”
switch to
“BARS”
.
2. Record the color bar signal.
3. Click the
“9. Head Clogging Detection Level
Confirmation”
of the VTR adjustment software.
4. Confirm that the WARNING condition. (“RF” is
displayed on LCD, Tally lamp is blinking, Alarm sound)
5. Click
“OK”
.
6. Confirm that the WARNING condition. (“RF” is
displayed on LCD, Tally lamp is blinking, Alarm sound)
7. Click
“OK”
.
8. Confirm that the WARNING condition. (“RF” is
displayed on LCD, Tally lamp is blinking, Alarm sound)
9. Click
“OK”
.
10. Confirm that the WARNING condition. (“RF” is
displayed on LCD, Tally lamp is blinking, Alarm sound)
11. Click
“OK”
.
12. Confirm that the WARNING condition. (“RF” is
displayed on LCD, Tally lamp is blinking, Alarm sound)
13. Click
“OK”
.
14. Confirm that the WARNING condition. (“RF” is
displayed on LCD, Tally lamp is blinking, Alarm sound)
15. Click
“OK”
.
16. Confirm that the WARNING condition. (“RF” is
displayed on LCD, Tally lamp is blinking, Alarm sound)
17. Click
“OK”
.
18. Confirm that the WARNING condition. (“RF” is
displayed on LCD, Tally lamp is blinking, Alarm sound)
19. Click
“OK”
.
TP6
TP2
Summary of Contents for AJ-D908MC
Page 3: ... 3 ...
Page 4: ... 4 AJ SDX900E ...
Page 5: ... 5 ...
Page 7: ... 7 AJ SDX900P ...
Page 8: ... 8 AJ SDX900E ...
Page 9: ...FCD0307NTNK96E440E441 ...
Page 279: ...CBA 1 MOTHER P C BOARD VEP89140A FOIL SIDE FOIL SIDE REF LOC P6 C6 P11 A6 P13 A6 ...
Page 310: ...CBA 32 MENU SW P C BOARD VEP80C58A FOIL SIDE COMPONENT SIDE ...
Page 312: ...PRE REC P C BOARD VEP83608A AJ YA903G FOIL SIDE COMPONENT SIDE CBA 34 ...