29
OPERATION menu
The underlining denotes the factory mode setting.
Setup Menus
Item
Setting
No.
Superimposed
display
No.
Superimposed
display
Description of setting
100
LOCAL ENABLE
0000
0001
DIS
ST&EJ
For selecting the switches which can be operated on the front panel in the
REMOTE mode.
0: None of the switches can be operated.
1: Only the STOP switch and EJECT switch can be operated.
101
TAPE TIMER
0000
0001
12H
24H
For selecting the CTL counter display.
0: ±12-hour display
1: 24-hour display
102
S/F/R EE SEL
0000
0001
EE
TAPE
For selecting the EE or VV output in the STOP, FF or REW mode.
0: E-E (electric modulation to electric playback) is output.
1: V-V (VTR to VTR recording) is output.
103
WIDE MODE
0000
0001
0002
AUTO
WIDE
NORMAL
For selecting the WIDE mode.
0: The mode is detected automatically.
1: The mode is forcibly treated as WIDE.
2: The mode is forcibly treated as NORMAL.
104
TAPE IN MOD
0000
0001
0002
0003
STOP
REW
PAUSE
PLAY
For selecting the operation which is to be performed when the cassette has
been inserted into the unit.
0: STOP
1: REWIND
2: PLAY PAUSE
3: PLAY
105
TAPE END MOD
0000
0001
0002
0003
STOP
REW
REW
EJ
EJECT
For selecting the operation which is to be performed when the tape has
arrived at the end.
0: STOP
1: REWIND
2: The tape is rewound and, upon completion of rewinding, it is ejected.
3: EJECT
106
AUTO BACK
0000
0001
OFF
ON
For selecting whether the tape is be automatically rolled back in order to
ensure frame to frame continuity.
0: The tape is not automatically rolled back.
1: The tape is automatically rolled back.
107
FORMAT SEL
0000
0001
0002
DVCPRO
DV
DVCAM
For selecting the format when an L cassette is to be used.
0: DVCPRO mode
1: DV mode
2: DVCAM mode
108
REC INHIBIT
0000
0001
OFF
ON
For selecting whether to inhibit recording on the unit.
0: Recording is allowed.
1: Recording is inhibited.
109
CAP. LOCK
0000
0001
2F
4F
For selecting the capstan lock mode.
0: The 2F lock mode is selected for the capstan.
1: The 4F lock mode is selected for the capstan.
110
FF. REW MAX
0000
0001
X32
X60
For setting the maximum FF and REW speed.
0: 32 times normal tape speed
1: 60 times normal tape speed
112
BGN PRESET
For setting the BEGIN point.
113
END PRESET
For setting the END point.
111
MEMORY MODE
0000
0001
0002
0003
OFF
M-STOP
REPT1
CONT
For setting the memory operation.
0: The memory operation is not performed.
1: The tape is stopped during FF or REW near the BEGIN point.
2: When the tape arrives at the end, it is rewound to the BEGIN point where
it stops.
3: When the tape arrives at the end, it is rewound to the BEGIN point and
played. This sequence is repeated.
Summary of Contents for AJ-D250P