ELE-18
1. Connect the WFM to the VIDEO OUT with 75ohm termination.
2. Open the SYSTEM SETUP screen and set the item
“SYSTEM MODE”
to
“1080/59.94i”
(MAIN MENU >
SYSTEM SETUP > SYSTEM MODE).
3. Select
“CAM(C)”
section after start up the PC EVR software, and click
“OK”
button.
4. Select
“Adjustment Tool”
in
“Tools(W)”
menu,
Adjustment Tool
screen will appear on screen.
5. Click
the
“Start”
button for
Video Level Adj.
.
6. Adjust Luminance level
“Y”
by clicking the adjustment button for
Y
so that it is within specification.
7. Adjust Burst level
“C”
by clicking the adjustment button for
C
so that it is within specification.
8. Change the system frequency to
50Hz
by clicking
“50Hz<->60Hz”
button on the
Adjustment Tool
screen.
Click the
“50Hz<->60Hz”
button. And click the
“Re-Boot Power”
button after the message
“TURN POWER
OFF”
is displayed on the LCD panel. The power of camera recorder is automatically OFF and ON.
9. Adjust Luminance level
“Y”
by clicking the adjustment button for
Y
so that it is within specification.
10. Adjust Burst level
“C”
by clicking the adjustment button for
C
so that it is within specification.
11. Click the
“Set”
button for
Video Level Adj.
to end of video level adjustment mode.
2-1-8. Video Output Level Adjustment
NTSC: Y = 714mV
7mV
Adjustment button (For NTSC)
Start button
Y
C
NTSC: C = 286mV
6mV
Adjustment value (For NTSC)
PAL: Y = 700mV
7mV
Set button
Adjustment button (For PAL)
Start button
PAL: C = 300mV
6mV
Adjustment value (For PAL)
Y
C