84
For Long and Trouble-Free Operation: Warning and Error Messages
• The OSD displays messages when warnings or errors occur.
Detailed Warning and Error Information
Display of information on operational warnings
Monitor display
Description
Deck operation
CANNOT REC
Displayed when data cannot be recorded on a P2 card.
[Meaning]
• The card is write protected.
• No more free space on the card.
• You are trying to record on a card that cannot be used.
• Card status changed during recording.
• VFR recording started but no active frame data was input.
• Recording was attempted when the unit was BUSY.
STOP
CANNOT LOOP REC
Displayed when ON is selected in menu SETUP - BASIC - LOOP REC and the P2 cards are
not available for recording.
[Meaning]
• The card is write protected.
• No more free space on the card.
• You are trying to record on a card that cannot be used.
• Card status changed during recording.
• Recording was attempted when the unit was BUSY.
STOP
CANNOT PLAY
Displayed when playback was interrupted due to a clip error or other factor.
[Meaning]
• Playback was attempted on card without any clips.
• Playback was attempted on a card not available for playback.
• Other causes that prevent playback or stops playback.
• Playback was attempted when the unit was BUSY.
STOP
TEXT MEMO INVALID
Displayed when a text memo cannot be recorded (for example, 100 or more text memos
have been recorded).
Operation
continues
INT SG
Displayed for the first 2 seconds when INT SG is selected in menu SETUP - VIDEO - INPUT
SEL or in menu SETUP - AUDIO - INPUT SEL and the REC
button is pressed to engage
EE mode.
Operation
continues
NO INPUT
Displayed for the first two seconds when the REC
button is pressed to enter EE mode
and INPUT SEL is set to a connector with no input except for analog audio signals.
Operation
continues
TEXT MEMO
Displayed for two seconds when a text memo is added.
Operation
continues
MARK ON / MARK OFF
Displayed for two seconds when a shot mark is added or deleted.
Operation
continues
SLOT SEL INVALID
Displayed when the SLOT SEL button (when assigned to a USER button) was pressed when
it is not possible to switch P2 card recording slot.
Operation
continues
BUSY
Displayed while clip information is being read or when clip configuration has changed. No
operations can be performed while BUSY is on the screen.
[Meaning]
• A card has been inserted or removed.
• Updating is in progress
• Recording post processing is in progress
• Other causes
Operation
continues
REF ERROR
Displayed when the REF IN connector signal differs from the system frequency or is not
synchronized with SDI input signals, or in other situations when synchronization with the
reference signal is not possible. The unit will not operate normally when this warning is
displayed. Check connections and input signals.
Operation
continues
Summary of Contents for AG-HPD24P
Page 97: ...97 ...