26
Fig.E3
1-3. Adjustment System
For performing the electrical adjustment, the following adjustment system is required.
The measuring board (VFK1308P) as shown in figure E2 has 2 types of RS-232C connectors 9pin D-sub connector and
M3 RS-232C connector.
A) 9 Pin RS-232C D-sub Connector
If an ordinary 9-pin RS-232C cross cable is available, connect it between the measuring board and personal
computer as shown in figure E2.
B) M3 RS-232C Connector
Also M3 RS-232C cable can be used instead of ordinary 9-pin RS-232C cross cable.
The part number of M3 RS-232C cable is VFK1395.