ELE-19
5. After adjustment has been completed, confirm that the portion
“T”
is within specification as shown below.
6. Click
“Close(C)”
button to escape this menu.
5-3. Luminance level adjustment
1. Connect the WFM (for NTSC) or the oscilloscope (for PAL) to the VIDEO OUT with 75ohm termination.
2. Double-click the adjustment item
“Luminance level”
in the main menu. The following screen will appear.
3. Adjust luminance level by pressing the arrow keys of keyboard so that it is within specification.
4. Click
“Write(E)”
button after adjustment has been completed.
T
T = 126 ± 1 µsec
HID
SPA
NTSC: A = 100 IRE
±
2IRE
PAL : A = 700 mVp-p
±
10mV