ELE-13
4-6-2. White balance adjustment (5100K) (Auto)
1. Set the Color Conversion filters (LB120: VFK1347), (LBA2: VFK1884) and (LBB6: VFK1888) to the CC Filter
Holder (VFK1345).
2. Set the one Step-down Ring (VFK1346) and two Step-up Rings (VFK1659, VFK1660) to the CC Filter Holder as
shown in figure.
3. Set the 72mm Attachment Ring (VFK1809) to the front of Lens.
4. Set the CC Filter Holder with Step-up & down Rings to 72mm Attachment Ring (VFK1809).
5. Aim the Camera-Recorder at grayscale chart under the Halogen lamp condition (3100K, 2000Lux).
6. Double-click the adjustment item
“White balance (5100K)”
in the main menu. The following screen will appear.
7. Click
“Execute(E)”
button. Automatic adjustment starts.
8. After adjustment has been completed, click
“Close(C)”
button to escape this menu.
CC Filter Holder
VFK1345
CC Filter
(LBB6)
CC Filter
(LBA2)
CC Filter
(LB120)
Step Up Ring
(49
→
62)
Step Up Ring
(43
→
49)
Set to 72mm Attachment Ring (VFK1809)
Step down Ring
(62
→
52)