MECH-2
1-3. Adjustment of S1 and T2 Post
LISTA linearity and Envelope waveform are adjusted by S1 and T2 post.
To adjust height of S1 and T2 post, below indicated operation is required.
1. Set to VCR mode in camera recorder and open the cassette cover.
2. Insert DV tape and confirm that the camera recorder is in the loading completion condition.
3. Close the cassette cover.
4. Unscrew the screw (A) and open the cassette cover.
1-4. Connection of EVR Tools
To performing the confirmation of envelope (item “1-11. Self-REC/PLAY Envelope Confirmation”), the following tools
are required.
NAME Part
Number
Pcs. Remark
Measuring Board
VFK1308P
1
30pin Flat Cable
VFK1317
2
EVR Connector Board
VFK1309A
1
NOTE:
Enable to use with VFK1309
Connection Adapter
VFK1763
1
60 to 30pin
Extension Cable
VFK1982
1
DC Cable
VJA1128 or LSJA0310
1
For DVX100B/DVX102B/DVC180MC
AC Adapter
-----
1
For DVX100B/DVX102B/DVC180MC
To confirm the envelope output, connect the Connection and Measuring Boards as described below.
1. Loosen the screw and remove the EVR COVER.
SCREW (A)
EVR COVER
SCREW