![Panametrics C-RL Instruction Manual Download Page 50](http://html1.mh-extra.com/html/panametrics/c-rl/c-rl_instruction-manual_3404851050.webp)
42
Model C-RL Installation Guide
4.8.2
C-RL Transducer Numbers 304, 305 and 308
Table 3:
Specification
Transducer Number
305
304
306
Primary Use
Small pipes
Low pressure, high
velocity; primarily
used with TAG
technology
Low pressure, high
velocity; primarily
used with TAG
technology
Installation Type
Clamp on
Material of Construction
316 stainless steel and plastic
Pipe Sizes
3/4 to 2”
(20 to 50 mm)
6 to 20”
(150 to 500 mm)
16 to 30”
(400 to 760 mm)
Consult Panametrics
for larger pipes.
Clamping Fixture
CFG-V1, CFG-V4
CFT-V8, CFT-V12, CFT-PI
Operating Frequency
1.0 MHz
500 kHz
200 kHz
Electrical Rating
200 V peak-to-peak, 5 mA
Ambient Temperature Range
North America: -20 to +75°C (-4 to +167°F)
Europe: -40 to +75°C (-40 to +167°F)
Process Temperature Range
North American/European safe areas: -40 to 130
o
C (-40 to 266
o
F)
ATEX/European hazardous areas: -40 to +75°C
North American Certification -
Explosion proof
Class I, Div 1,
Group B, C, D
European Certification -
Flameproof
II 2 G Ex d mb IIC T6 Gb
II 2 D Ex mb tb IIIC T80 °C Db
Tamb -40 to 75
o
C (-40 to 167
o
F)
KEMA 02ATEX2337 X
North American Certification -
Weatherproof
IP66, TYPE 4X
200Vpp, 5mA
European Certification -
Weatherproof
IP 66
Note:
The transducer is protected by a suitable fuse located in the flowmeter electronics. The fuse has a rating
corresponding with the short circuit current of the power supply.