11
LOAD LEVEL STATUS
Requests the load level, expressed as percentage of maximum.
Send Query to UPS: ?LOADSTAT<CR>
Action: Load level will be displayed
Response: $LOAD = xxx<CR>
xxx is the load level (percentage of maximum load) expressed in decimal
format. If the value is less than 100, the hundreds digit is
represented with a 0.
BATTERY LEVEL STATUS
Requests the battery level, expressed as a percentage of maximum (full
charge).
Send Query to UPS: ?BATTERYSTAT<CR>
Action: Load level will be displayed
Response: $BATTERY = xxx<CR>
xxx is the battery charge level (percentage of maximum charge) expressed in
decimal format. If the value is less than 100, the hundreds digit is represented
with a 0.
LIST CONFIGURATION
Requests a list of all configurable parameters and current settings.
Send Query to UPS: ?LIST_CONFIG<CR>
Action: List of configurable parameters and current settings will be displayed.
Response: $BTHRESH = level<CR>
$BUZZER = mode<CR>
$AVR = mode<CR>
$FEEDBACK = mode<CR>
$LINEFEED = mode<CR>
$BRIGHTNESS = xxx<CR>
$SCROLL_MODE = xxx<CR>
$SLEEP_MODE = xxx<CR>
VOLTAGE
Requests the input voltage level.
Send Query to UPS: ? VOLTAGE <CR>
Response: $ VOLTS-IN = v v v <CR>
v v v is the input voltage.
CURRENT
Requests the output current.
Send Query to UPS: ? CURRENT <CR>
Action: send Query to UPS: ? CURRENT <CR>
Response: $ CURRENT = c c c <CR>
c c c is the output current in amps.
LIST OF ALL COMMANDS AND QUERIES
Send Query to UPS: ?HELP<CR>
Action: List of all commands and queries will be displayed
Response:
!ALL_ON<CR>
!ALL_OFF<CR>
!SWITCH<CR>
!SET_BATTHRESH<CR>
!SET_BUZZER<CR>
!SET_AVR<CR>
!SET_FEEDBACK<CR>
!SET_LINEFEED<CR>
!RESET_ALL<CR>
!SET_BRIGHT<CR>
RESPONSES & MESSAGES OUTLET STATUS CHANGE CONDITION
RESPONSE
Outlet Bank 1 changes state $BANK1 = status<CR>
Outlet Bank 2 changes state $BANK2 = status<CR>
Outlet Bank 3 changes state $BANK3 = status<CR>
Outlet Bank 4 changes state $BANK4 = status<CR>
status = {ON, OFF}
POWER BUTTON STATUS CHANGE CONDITION RESPONSE
Power Button changes ON/OFF status $BUTTON = status<CR>
status = {ON, OFF}
POWER FAULT STATUS CHANGE CONDITION RESPONSE
Overvoltage State $PWR = OVERVOLTAGE<CR>
Undervoltage State $PWR = UNDERVOLTAGE<CR>
Lost Power State
$PWR = LOST POWER<CR>
Test Mode
$PWR = TEST<CR>
Recovery Mode
$PWR = RECOVERY<CR>
Normal Operation Mode
$PWR = NORMAL<CR>
Low Battery
$LOWBAT<CR>
AVR Stage
$AVRSTATE = state<CR>
state = {BOOST, BUCK}
Remaining Backup Time
$TIME = xxx<CR>
xxx = backup time
Battery State
$BATTSTATE = xxx<CR>
xxx = {CHARGE, DISCHARGE, FULL}
Power Control Software
Complete Instructions are available by clicking on Help on the Power
Control Software welcome screen
!SET_SCROLLMODE<CR>
!SET_SLEEPMODE<CR>
?ID<CR>
?OUTLETSTAT<CR>
?POWERSTAT<CR>
?VOLTAGE<CR>
?LOADSTAT<CR>
?BATTERYSTAT<CR>
?LIST_CONFIG<CR>
?HELP<CR>