© Pan Acoustics GmbH
V 1.0
Page 19 of 24
Manual
The 100 V variant of the loudspeaker P 8-15-Pi | IP65 is equipped with a 5-pin connection cable with
numbering (1-5) of 5 m length. The connection cable is permanently connected to the loudspeaker
at the factory and can be shortened to the required length. In addition to the connection cable, the
loudspeaker P 8-15-Pi | IP65 features a maintenance-free pressure equalisation element for weather
protection.
8.2.4. P 8-15-Pi | IP65 (100 volts)
Connection of the loudspeaker to the 100 V network:
•
shorten the connection cable to the desired or required length
•
remove approx. 5 cm of cable sheath at the end of the cable and expose the wires
•
strip the desired wires (1-4) + (5) for the power tap
•
use heat shrink tubing to insulate the unneeded wires individually against short circuits
•
fi t the wires with wire end ferrules
•
connect the connection cable to the 100 V network according to the technical rules
Connection cables must not be used for fi xing or suspending loudspeakers.
WARNING
The numbers on the wires (1-5) correspond to the following power taps:
1 = 100% | 2 = 50% | 3 = 25% | 4 = 12.5% | 5 = 0 V
NOTICE
8.3.
Operation on the power amplifi er
The loudspeaker P 8-15-Pi must be operated on a correctly confi gured DSP amplifi er or amplifi er with
upstream audio DSP. The amplifi er to be used must be chosen according to the technical data of the
loudspeaker.
Technical data --> see chapter 17 ”Technical data loudspeaker”.