background image

© Pan Acoustics GmbH   

 V 1.0    

Page 14 of 18

Manual

14. Warranty

Pan Acoustics GmbH

Schweigerstr. 13d

38302 Wolfenbüttel

Germany

Tel.: +49 (0) 5331 900 95 70

Fax:  +49 (0) 5331 900 95 79

E-mail: [email protected]

15. Contact address

Pan Acoustics 

stands by its products and gives up to 

10 years warranty

 on 

its loudspeakers for 

any material or manufacturing defects. New products manufactured in accordance with protection 

classes  IP54  and  IP65  as  well  as  digital  audio  interfaces  (Dante

®

)  from  Audinate  Pty  Ltd  and  re-

chargeable batteries are excluded from the 10-year warranty. A warranty period of 3 years is granted 

for loudspeakers in accordance with protection classes IP54 and IP65. For further information on the 

warranty, please refer to the Pan Acoustics warranty conditions.

https://www.pan-acoustics.de/en/service/warranty

16. Mounts

Recommended mounts for mounting products from the Pan Speaker series on walls and ceilings or 

for mobile use include:

Tripod mount

Wall mount, TWM II

Wall/ceiling mount P/PB 04 

with access protection

Stand for P/PB xx 

loudspeaker systems

Wall mount, TWM III

Ceiling mount (BK)

Depending on the length and weight of the loudspeaker, a corresponding number of mounts must be 

used and, if necessary, additional measures for stability or fall protection must be taken.

Information on additional measures or the number of mounts to be used can be found in the manual 

of the corresponding accessory. If you have any technical questions, you can also contact our support 

team at [email protected].

NOTICE

Summary of Contents for P 04

Page 1: ...Acoustics reserves the right to modify products without prior notice All products are designed developed and manufactured by Pan Acoustics in Germany Doc No 2022_01523 DOCUMENTATION B E A M 2 LINE SP...

Page 2: ...n a safe place so that it is available when needed If the product is resold the document must be handed over to the new owner in printed or electronic form Pan Acoustics reserves the right to change u...

Page 3: ...racket 10 8 2 Electrical connection 10 8 2 1 P 04 RJ low impedance 10 8 3 Important notice regarding the network cable and amplifier power 12 8 3 1 Permissible cable cross sections and lengths 12 8 3...

Page 4: ...on the product properties available at the time of preparation and the safety regulations applicable at that time This operating manual describes the setup function and connection of the Pan Speaker l...

Page 5: ...rly marked and secured against accidental operation if the product shows signs of visible damage contains loose parts no longer works awlessly has been stored for a long time under unfavourable condit...

Page 6: ...ured and labelled accordingly It must also be ensured that no intentional or accidental operation by third parties is possible The loudspeaker is suitable for indoor operation In outdoor areas the lou...

Page 7: ...according to the acting forces that may occur through lever e ects In case of doubt as to the type and composition of the building structure consult a structural engineer CONNECTION OF THE LOUDSPEAKE...

Page 8: ...t The bracket features three fixing points for mounting e g on a building surface To mount the U bracket on a surface it must first be removed from the loudspeaker After mounting the bracket on the wa...

Page 9: ...of 18 Manual Step 3 Secure plastic washer Mount the bracket on the desired building sur face When assembling position the plastic washers appropriately Assembly is done in reverse order NOTICE Step 2...

Page 10: ...24 AWG network cables Alternatively an adapter cable is available to operate the loudspeaker with DSP power amplifiers that do not have an RJ45 compatible port The U bracket can be swivelled from the...

Page 11: ...nect the network cable to the socket of the loudspeaker and snap it into place Step 2 Run the network cable with the RJ45 plug to the loudspeaker Check the locking mechanism of the connec tion cable f...

Page 12: ...rably depending on the cable cross sec tion To prevent a cable fire the cross section of the cable must be su ciently dimensioned WARNING 1 8 CAT5e or CAT6 cables are suitable for adapted power transm...

Page 13: ...k the enclosure for damage Check the connection cable for damage 10 Service and repair 11 Maintenance measures The declaration of conformity for the relevant product from the Pan Speaker series can be...

Page 14: ...IP54 and IP65 For further information on the warranty please refer to the Pan Acoustics warranty conditions https www pan acoustics de en service warranty 16 Mounts Recommended mounts for mounting pro...

Page 15: ...power amplifier Sensitivity 92 dB 1 W 1 m Maximum SPL 126 dB peak 1 m Impedance 4 ohms Horizontal radiation pattern 100 Vertical radiation pattern 30 Connections 1 x RJ45 Temperature range 10 C to 50...

Page 16: ...Pan Acoustics GmbH V 1 0 Page 16 of 18 Manual 18 Technical drawing loudspeaker 18 1 P 04 RJ 506 mm 107 mm 116 mm...

Page 17: ...Pan Acoustics GmbH V 1 0 Page 17 of 18 Manual 18 2 P 04 RJ mB 522 mm 137 mm 152 mm 107 mm...

Page 18: ...ACT Pan Acoustics GmbH Schweigerstr 13d D 38302 Wolfenb ttel Germany Tel 49 0 5331 900 95 70 Fax 49 0 5331 900 95 79 E mail contact pan acoustics de www pan acoustics de QUALITY MADE IN GERMANY SINCE...

Reviews: