21
Operation of timers
This section provides timer operation via the unit, but it is possible to
control the timers by using the remote control.
Please ensure that the main power is ON
•
While main power is ON.
ON/OFF
light glows
green or glows red after ignition.
•
Please ensure the
TIMER’s
are programmed as
per previous section.
Please ensure you take the following steps.
•
Is the gas valve fully opened?
•
Set temperature is adjusted to desired
temperature?
•
There are no objects in front of the louvre to
block the air outlet.
Press the
TIMER/S
button/s.
•
You can select
TIMER 1
or
TIMER 2
or both by
pressing the
TIMER 1
and/or
TIMER 2
buttons.
•
Selected
TIMER
’s [ON] [OFF] lights will glow.
•
The
TIMER
operation is not set and will not
function if the
TIMER
’s “ON” and “OFF” lights
are not glowing.
•
If during operation combustion shuts down then
the
ON/OFF
light will glow green.
Pre-heat function:
[At one hour prior to the set time the heater will
operate automatically – Example; If the ON time is
set for 5.30AM then the heater will automatically
start up at 4.30AM]
•
Selected
TIMER 1
or
TIMER 2
[ON] light
flashes.
•
ON/OFF
light turns from green to red.
[Timer operation start time]
•
Selected
TIMER
’s [ON] [OFF] light flashes.
[Timer Operation shut down time]
•
Selected TIMER’s [ON] [OFF] light glows.
•
Combustion shut down and the heater stands
by for timer operation.
•
ON/OFF
light glows green.
1
2
3
4
5
6