5. Error Code [61] (Fan Failure) is displayed.
Refer to the previous C-4 (Error Code [61]).
6. Error Code [21] (Malfunction of Air Intake Filter Switch) is displayed. (Indoor Model Only)
NO
YES
Replace Air Filter Switch Assy.
*5 Measure the voltage and resistance of connector .
Between both White wires:
Voltage: Less than 1 VDC
Resistance: 1 ohm
(Measure these after the air filter switch is ON.)
O
Is the
Air Filter Switch ON?
*5
Replace Burner Control Assy.
NOTE: When performing and/or servicing the water heater without front cover (opened),
operate it by pushing the air filter switch (ON).