background image

A. Outdoor Water Heater Location

q

Outdoor water heaters must be installed outdoors.

q

Protected from freezing temperatures.

B. Indoor Water Heater Location

q

Close to area of vent termination.

q

Indoors and protected from freezing temperatures.

C. Outdoor and Indoor Water Heater Location

q

Proper clearance from combustible surfaces observed.

q

Sufficient fresh air supply for proper operation of
water heater.

q

Air supply free of corrosive elements and 
flammable vapors.

q

Provisions made to protect area from water damage.

q

Sufficient room to service heater.

q

Combustible materials, such as clothing, cleaning
materials, rags, etc. clear of the heater and 
vent piping.

q

Water heater is properly attached to the wall.

D. Water Supply

q

Water supply has sufficient pressure.

q

Air purged from water heater and piping.

q

Water connections tight and free of leaks.

q

Water filter is clean and in place.

q

Materials used are as instructed in this manual.

q

Water pipes are insulated and protected from
freezing.

E. Gas Supply

q

Gas type matches rating plate.

q

Gas supply pressure is sufficient for the water heater.

q

Gas line equipped with shut-off valve, union and
sediment trap.

q

Approved pipe joint compound used.

q

Soap and water solution used to check all connections
and fittings for possible gas leak.

q

Gas Company inspected installation (if required).

F. Relief Valve

q

Pressure Relief Valve properly installed and discharge
line run to open drain.

q

Discharge line protected from freezing.

G. Venting (Indoor Water Heaters Only)

q

Vent pipe material should be category III and meet
UL1738 in US and ULC S636 in Canada.

q

Vent connector(s) pitched (1/4” per foot of length
minimum) DOWNWARD or UPWARD to
termination. If UPWARD, a condensate trap must be
installed close to the heater. See page 14.

q

Vent connector(s) securely fastened together with
high temperature silicone (500°F [260°C]) and 
air-tight.

q

All vent runs are properly supported.

q

Vent terminal is properly installed.

q

Sufficient combustion air is available.

q

Maximum and minimum vent lengths are observed.

H. Electrical Wiring

q

Voltage matches rating plate.

q

Water heater is properly grounded.

q

Supply cord and/or wiring meets all local codes.

Installation Check List

25

Summary of Contents for PH-16 FISN

Page 1: ...ater and two to the owner operator to explain the features operation safety precautions maintenance and troubleshooting of the water heater This manual also includes a parts list It is very important...

Page 2: ...THIS MANUAL FOR YOUR RECORDS Write the model and serial numbers here You can find them on a label on the appliance Staple sales slip or cancelled check here Proof of the original purchase date is nee...

Page 3: ...well as other flammable materials and liquids adhesives solvents paint thinners etc and the vapors they produce are extremely dangerous DO NOT handle use or store gasoline or other flammable or combus...

Page 4: ...emote control and a dip switch adjustment Only qualified service personnel should perform this adjustment Only factory authorized remote control s should be used Notice When this water heater is suppl...

Page 5: ...P gas must be used with great caution It is heavier than air and will collect first in lower areas making it hard to detect at nose level l Before attempting to light the water heater make sure to loo...

Page 6: ...ATION READ ALL INSTRUCTIONS BEFORE USING WARNING For your safety the information in this manual must be followed to minimize the risk of fire or explosion electric shock or to prevent property damage...

Page 7: ...y result in severe burns death or property damage The water heater must be located so it is not subject to physical damage for example by moving vehicles area flooding etc l The water heater should be...

Page 8: ...dentally spilled l The water heater should be installed as close as practical to the vent termination to minimize vent length and the number of elbows required for venting l The water heater should be...

Page 9: ...ter heater warranty is voided when failure of the heater is due to operation in a corrosive atmosphere NOTICE The water heater should not be installed near an air supply containing halogenated hydroca...

Page 10: ...service Additional installation information for the Commonwealth of Massachusetts is located on the page 36 of this manual DANGER Failure to install the appliance vent adapter and properly vent the wa...

Page 11: ...he appliance vent adapter manufacturer s instructions Appliance Vent Adapter Water Heater Exhaust Flow A B High Temp Sealant Collar Clamp Draining the Condensate Provision should be made to collect an...

Page 12: ...1 foot 300 mm above opening 6 inches 15 cm for appliances 10 000 Btuh 3 kW 9 inches 23 cm for appliances 10 000 Btuh 3kW and 50 000 Btuh 15kW 12 inches 30 cm for appliances 50 000 Btuh 15kW K Clearanc...

Page 13: ...posed vent pipe of indoor water heaters outside of building Guard vent against accidental contact with people and pets Install outdoor water heater such that air inlet and flue outlet is above anticip...

Page 14: ...s Reinstall the decorative sheathing around the Wall Thimble This assembly may be painted to match the exterior decor l Attach a Paloma approved 3 7 6 cm screened 90 elbow termination to the female en...

Page 15: ...vent purchased from the manufacturer Chase Requires 6 15 cm Clearance to Combustibles Firestop Firestop Roof Jack Adjustable Roof Flashing Vent Adapter 3 8 cm Clearance Support Hanger Condensate Trap...

Page 16: ...th cold and hot water supply lines DO NOT cover the drain or pressure relief valve To ensure proper operation of the water heater the following water pressure guidelines should be followed l Operation...

Page 17: ...Installation of unions or flexible copper connections are recommended on the HOT and COLD water lines so that the water heater may disconnect easily for servicing if necessary Install a Check Valve be...

Page 18: ...codes govern the installation of relief valves If local codes require that a temperature and pressure relief valve should be installed the manufacturer recommends a type 40XL Watts T P relief valve or...

Page 19: ...use excessive force over 31 5 ft lbs 42 7 Nm in tightening the pipe particularly if teflon pipe compound is used as the unit may be damaged The inlet gas pressure to the water heater must not exceed 1...

Page 20: ...te controls can connect to the water heater Therefore a maximum of three controls can connect to the water heater No other manufacturer s controls are suitable for use with this water heater DO NOT at...

Page 21: ...e remote control over the base plate Ensure the projections in the base plate fit into the housings in the remote control l l Fix the control to the base plate at the bottom of the remote control usin...

Page 22: ...nnection when servicing controls Wiring errors can cause improper and dangerous operation Verify correct operation after servicing BK 8 R GR Y B O W BR WATER FLOW SENSOR OVER HEAT LIMITER BK GND GND T...

Page 23: ...codes or plumbing authority requirements may vary from the instructions or diagrams provided and take precedent over these instructions Vacuum Relief Valve Not Supplied If required install per local c...

Page 24: ...ket is to reduce the standby heat loss encountered with storage tank heaters This water heater does not store water making an insulation blanket unnecessary The manufacturer s warranty does not cover...

Page 25: ...pply q Gas type matches rating plate q Gas supply pressure is sufficient for the water heater q Gas line equipped with shut off valve union and sediment trap q Approved pipe joint compound used q Soap...

Page 26: ...s label 2 Turn off all electric power to the appliance 3 Do not attempt to light the burner by hand 4 Turn the Gas Shutoff Valve located on the outside of the unit clockwise to the OFF position 5 Wait...

Page 27: ...alves are available for reducing point of use water temperature by mixing hot and cold water in branch water lines Contact a licensed plumber or the local plumbing authority for further information Se...

Page 28: ...otter water increases the risk of scald injury Always supervise young children or others who are incapacitated The water heater is equipped with a device that will shut off the gas supply to the burne...

Page 29: ...nd or cleaning ensure proper operation by turning on a hot water faucet Housekeeping Before performing Housekeeping tasks to this water heater turn the unit off and disconnect the power supply Vacuum...

Page 30: ...burner flame Blue flames should be seen when the main burner is firing See figure on page 34 for location of sight glass If any unusual burner operation is noted the water heater should be shut off u...

Page 31: ...eezing conditions even for a short period of time be sure to drain all water from the unit as instructed above Exposure to freezing conditions can occur from down draft of venting system or from insta...

Page 32: ...lfunctions if applicable l Check and replace if necessary Error code displayed on remote control l See instructions for Error Code and if required contact a dealer for service Not enough water demand...

Page 33: ...erial or vent configuration l Open the Gas shutoff valve fully l Contact gas utility company l Fill up LP Gas container or replace with a new cylinder of LP Gas l Bleed all air from gas lines l Ensure...

Page 34: ...t connectors or other safety devices Refer repairs to qualified service personnel WARNING For your safety DO NOT attempt to disassemble this unit for any reason Indoor Water Heater Gas Supply Unit Cov...

Page 35: ...bove then continue as listed below l Press the SW1 button on the left hand side of the PCB for more than 1 second The LED on the PCB starts illuminating continuously At the same time the display of th...

Page 36: ...time of completion of installation the owner shall have a period of thirty 30 days to comply with the above requirements provided however that during said thirty 30 day period a battery operated carbo...

Page 37: ...d to one 1 year from the Effective Date WARRANTY EXCLUSIONS This Limited Warranty will not cover a Service trips to your home to teach you how to install use or maintain this water heater or to bring...

Page 38: ...rts Paloma determines that a defect exists Paloma shall furnish replacement part s in full settlement of its warranty obligations Purchasers shall be required to return at purchasers expense the defec...

Page 39: ...This page was intentionally left blank...

Page 40: ...Paloma Industries Inc 2151 Eastman Avenue Oxnard CA 93030 PRINTED IN JAPAN 31 80171 00...

Reviews: