Paloma PG-451S Operating Instructions Manual Download Page 8

 

 

 

  This room heater must be installed in accordance with this advice to be covered by the Paloma 

warranty.  

  This room heater is suitable for indoor installation only. 

  This appliance must be installed in accordance with: 

o

  Local Gas Fitting Regulations 

o

  Municipal Building Codes 

o

  Australian Standard for Gas Appliance Installations AS/NZS5601.1:-2010 

o

  Any other relevant Statutory Regulation 

o

  Manufacturer’s installation instructions 

  This heater must be installed within the minimum clearances (Refer to page 9). These 

clearances must be maintained at all times. 

  Do not install in a room with inadequate ventilation – refer to Australian Standard 

AS/NZS5601.1:-2010. 

  Do not install on an uneven surface or a vibrating floor. 

  Do not install directly on to carpet, timber floor, vinyl floor or cork floors. Heat emanating from 

these appliances may discolour the carpet or damage your floor. It is recommended that a mat 
or flat board be placed in front of this appliance extending at least 800mm in front of it. 

  Do not install near a door or windy location or under shelves or in a confined space. E.g.: 

fireplace. 

  Do not install in a bedroom, bathroom, combined living/sleeping areas, toilets or sauna. 

  Do not install where flammable materials are likely to come into contact with the heater. 

  Do not install where water may splash or near another heat source. 

  Do not install in a caravan, mobile home or recreational vehicle. 

  Do not connect to a Propane (LPG) gas cylinder 

indoors

  This appliance is not designed to be built into walls or cupboards. 

  If you move house check the gas type in the house where you are moving to. 

  The bayonet plug on the factory fitted flexible hose simply plugs into your bayonet fitting.  

  Do not place heater against wall or on a shelf. 

  Always place heater on flat surface and away from strong draughts. 

  Do not move the heater while it is in operation. 

  When the heater is operated for the first time or after long periods of non use a slight odour may 

be emitted, this is normal. However if odours persist switch off the heater and contact Rheem 
Service. 

 

Keep heater away from curtains or any inflammable materials as illustrated below.  

 
 

 

 

 

 
 
 
Minimum clearances - 30 cm from rear and sides, 100 cm from top and front are required from 
heater  
 

Installation 

Summary of Contents for PG-451S

Page 1: ...2 This appliance must be installed in accordance with a Local Gas Fitting Regulations b Municipal Building Codes c Australian Standard for Gas Appliance Installations AS NZS5601 1 2010 d Any other re...

Page 2: ...pecifications 4 Preparation 5 Safety Instructions 5 Danger 5 Warnings 6 Caution 7 Installation 8 Regular Care Maintenance 10 Operating Instructions 11 Trouble Shooting Guide 12 Warranty 13 Service Spa...

Page 3: ...stability Portability these heaters can be moved from room to room and stored away over the summer months Manufactured in Japan Safety Features Anti tilt Safety Switch automatically shuts off gas flo...

Page 4: ...4 Specifications...

Page 5: ...surance protecting their workmanship for 6 years Make sure you use a licensed person to install this heater and ask for a compliance certificate Message from the Victorian Plumbing Commission To ensur...

Page 6: ...he heater It may cause a fire or the pressure in the aerosol can may increase resulting in an explosion Do not post or allow children to post articles such as paper cloth or any other foreign material...

Page 7: ...se ensure you ventilate the room immediately for satisfactory combustion Ventilate room occasionally every 30 minutes with window or ventilating fan when heater is used continuously or in a closed roo...

Page 8: ...oor or windy location or under shelves or in a confined space E g fireplace Do not install in a bedroom bathroom combined living sleeping areas toilets or sauna Do not install where flammable material...

Page 9: ...sure to correctly fasten the hose to the bayonet connection Check the condition of the gas hose Old or decayed rubber PVC hoses should not be used Only use hose supplied with the heater or supplied b...

Page 10: ...ents Remove Front Guard and wipe Reflector with soft and dry cloth How to remove front guard lift up the guard and pull out low end How to install Front Guard reverse procedure Wipe parts with soft dr...

Page 11: ...ir in pipe is completely discharged If burner fails to light repeat ignition procedure 3 Regulate heat according to room size Pushing down Heat Settings Lever decreases heat to half capacity Do not ke...

Page 12: ...flame failure 2 OXYGEN DEPLETION SAFETY DEVICE If the oxygen levels drop below a safe level the oxygen depletion device will cut off the supply of gas to the heater 3 TILT SWITCH If the heater is knoc...

Page 13: ...nent is replaced under this warranty the balance of the original warranty period will remain effective The replacement does not carry a new Paloma warranty 3 Where the heater is installed outside the...

Page 14: ...nd that there is no fault with the appliance and the issue s are related to the installation or is due to the failure of electric or gas supplies 12 If you require a call out and we find that the faul...

Page 15: ...r 2 Rheem will arrange for the radiant heater to be tested and assessed on site 3 If Rheem determines that you have a valid warranty claim Rheem will repair or replace the radiant heater in accordance...

Page 16: ...ailer try the following 1 Please read these instructions carefully 2 Refer to trouble shooting guide page 12 3 Contact Rheem Service These Paloma models have been certified by the Australian Gas Assoc...

Reviews: