4
•
5.9 Star Energy rating.
•
One touch ON/OFF button.
•
Electronic
ignition.
•
Room temperature adjustment (Refer Page 7).
•
Economy function (Refer Page 8).
•
Filter Clean Warning Device - When the air filter is clogged or hot-air outlet is blocked, the filter safety
device will switch off the heater and the filter light will flash.
•
Anti-tilt Safety Switch automatically shuts off gas flow if the heater is knocked or bumped.
•
Oxygen Depletion Safety System automatically shuts off gas flow if the oxygen level in the room drops
below a safe level.
•
Flame Failure Device prevents flow of gas to burner if ignition fails or flame goes out.
•
Power Failure Device prevents flow of gas to burner if there is a power failure.
•
Overheat Safety Device – if the fan stops rotating for any reason the overheat switch shuts off the gas
supply.
•
Manufactured in Japan.
MODEL
PG-311F
PG-S311F
Type
Convection Heater
Convection Heater
DIMENSIONS: (mm)
436 x 531 x 206
436 x 531 x 206
(Approx: Height x Width x Depth)
GAS INPUT
LPG & NG
LPG & NG
High (MJ/h)
13.5
13.5
Low (MJ/h)
5.2
5.2
Output (kW)
3.4
3.4
HOSE Connections (mm)
Φ
9.5
Φ
9.5
STAR ENERGY RATING
5.9
5.9
MINIMUM ROOM SIZING (Cu.M)
33
33
COLOUR
Off White
Silver
NET WEIGHT (KGS)
10.9
10.9
(1) Remove heater from carton.
(2) Please ensure that the gas specified on the rating plate matches your gas supply. Using a different type
of gas may cause an explosive ignition resulting in injury, damage to heater or malfunction of the oxygen
depletion safety system. Do not install heater if it is the wrong gas type. Please contact your place of
purchase immediately.
(3) Check room sizing – refer specifications. Do not install if the actual room size is less than the specified
minimum room size requirements.
(4) A dedicated 240V Earthed 10 Amp power point must be used with this heater.
Notice to Victorian Customers:
This appliance must be installed by a licensed person as required by the
Victorian Building Act 1993. Only a licensed person will give you a compliance certificate showing that the
work complies with all relevant standards. Only a licensed person will have insurance protecting their
workmanship for 6 years. Make sure you use a licensed person to install this heater and ask for a
compliance certificate. – Message from the Victorian Plumbing Commission.
Preparation
Specifications
Features