background image

7

MISO 48 FIREBOWL Match-lit | Installation & Owner's Manual

BURNER MEDIA & DECORATIVE TOPPING

METAL TABLE TOP 

(OPTIONAL)

DECORATIVE TOPPING MEDIA (VARIOUS):

- FILL TOPPING TRAY  

- COVER BURNER MEDIA

- KEEP BELOW LID LINE

BURNER MEDIA:

CRUSHED GLASS (NG) or LAVA ROCK (LP)

- FILL BURNER MEDIA TRAY

- COMPLETELY COVER BURNER RING

VENTILATION HOLES:

DO NOT BLOCK

CAUTION: Do not use any media over the 

burner that have not been supplied by Paloform. 

Landscape stone or other natural or manufactured 

materials may explode when heated.

Summary of Contents for MISO 48

Page 1: ...ING FOR OUTDOOR USE ONLY Installation and service must be performed by a qualified installer service agency or gas supplier INSTALLER Leave this manual with the appliance CONSUMER Retain this manual f...

Page 2: ...ANSI Z223 1 NFPA 54 or the International Fuel Gas Code 3 Keep the appliance area clear and free from combustible materials gasoline and other flammable vapors and liquids 4 Do not burn solid fuel in...

Page 3: ...level surface 4 AIR VENTS Do not block ventilation holes in base if applicable see p 4 5 GAS PROPANE Supply line is routed through the base of the unit and must be installed by licensed trades Space i...

Page 4: ...TILATION HOLES GAS ELECTRICAL SUPPLY OPENING 6 x 8 152 x 203 NATURAL GAS PROPANE Burner Model CIR E 24 CIR E 24P Max Heat Input 140 000 BTU h 140 000 BTU h Inlet Pressure Min 4 5 W C 11 0 W C Inlet Pr...

Page 5: ...5 MISO 48 FIREBOWL Match lit Installation Owner s Manual REQUIRED CLEARANCES FIG 1 MINIMUM CLEARANCES TO COMBUSTIBLES 82 11 0 CLEARANCE BELOW...

Page 6: ...stance during this time ASSEMBLY TO ASSEMBLE THE FIRE PIT 1 Connect the Burner Assembly to the gas propane supply using the supplied flex connector and following the instructions on page 8 2 Carefully...

Page 7: ...L TOPPING TRAY COVER BURNER MEDIA KEEP BELOW LID LINE BURNER MEDIA CRUSHED GLASS NG or LAVA ROCK LP FILL BURNER MEDIA TRAY COMPLETELY COVER BURNER RING VENTILATION HOLES DO NOT BLOCK CAUTION Do not us...

Page 8: ...en flame to check for a leak Apply a mixture of liquid soap and water to all joints Bubbles forming on joints while the gas is running indicate a leak Correct all leaks at immediately Test Pressures i...

Page 9: ...tance or additional information consult a qualified installer service agency or the gas supplier Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this appliance INI...

Page 10: ...lockwise until it stops 3 Push the control key in until it stops and hold in this position 4 Apply a flame to the lighting port with a barbecue lighter The pilot flame will ignite 5 Continue to hold t...

Page 11: ...ELEMENT AND PILOT Inspect the burner at regular intervals at least twice a year Keep the burner and pilot area clean by vacuuming or brushing Make sure the burner porting and burner air openings are f...

Page 12: ...eck reset gas regulator pressure Gas odor even when manual valve is in the OFF position 1 Gas leak See Warning statement below 2 Main gas valve defective 1 Locate and correct all leaks see Checking Ga...