SAFETY INFORMATION

 WARNINGS:

IMPORTANT: This appliance should 

be inspected before use and at 

least once annually by a qualified 

service person.

More frequent cleaning may 

be required as necessary. It 

is imperative that the control 

compartment, burners and 

circulating air passageways of the 

appliance be kept clean.

DANGER: Carbon monoxide 

poisoning can lead to death!

CARBON MONOXIDE POISONING:

Early signs of carbon monoxide 

poisoning resemble the flu, with 

symptoms including headache, dizziness, 

or nausea. If you experience these signs, 

the Fire Pit may not be working properly. 

Get fresh air at once! Have the Fire Pit 

serviced. Some people are more affected 

by carbon monoxide than others, 

including pregnant women, people with 

heart or lung disease or anemia, those 

under the influence of alcohol, and those 

at high altitudes.

NATURAL GAS AND PROPANE: 

To assist in detecting leaks, an odorant 

has been added to natural gas and 

propane. However, this odorant can fade, 

and gas may be present even though no 

odor exists. Make certain you read and 

understand all warnings. Keep this manual 

for reference. It is your guide to safe and 

proper operation of this appliance.

WARNING:

 Any modification to this appliance or its 

controls can be dangerous.

1.  This appliance, as supplied, is only for use with the 

type of gas indicated on the rating plate.

2.  When this appliance is connected to a fixed piping 

system, the installation must conform to local codes, 

or in the absence of local codes, to the National 

Fuel Gas Code, ANSI Z223.1/NFPA 54, or the 

International Fuel Gas Code.

3.  Keep the appliance area clear and free from 

combustible materials, gasoline and other flammable 

vapors and liquids

4.  Do not burn solid fuel in this appliance. Do not use 

this appliance to cook food or to burn paper or other 

objects.

5.  Children and adults should be alerted to the 

hazards of high surface temperatures and should 

stay away to avoid burns or clothing ignition.

6.  Clothing or other flammable materials should not 

be hung from the appliance, or placed on or near 

the appliance.

7.  Young children should be carefully supervised 

when they are in the area of the appliance.

8.  Do not use the appliance if any part has been under 

water. Immediately call a qualified service technician 

to inspect the appliance and to replace any part of 

the control system and any gas control which has 

been under water.

9.  Inspect the appliance before each use.

10. Turn the appliance off and let cool before servicing, 

installing, repairing or covering. Any guard or other 

protective device removed for servicing the 

appliance must be replaced prior to operating the 

appliance. Only a qualified service person should 

install, service, or repair the appliance.

HIGH ALTITUDE INSTALLATION

The appliance is rated for installations up to 4500’ (1372 

m) above sea level. Above 4500’ the appliance must be 

derated at the factory for the appropriate altitude unless 

the local fuel is pre derated.

LOCAL CODES

Install and use your Outdoor Fire Pit with care. Follow 

local codes. In the absence of local codes, use the latest 

edition of The National Fuel Gas Code ANSI Z223.1/

NFPA 54 available from:

American National Standards Institute Inc.

1430 Broadway

New York NY 10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy MA 02269.

Summary of Contents for Bento 42 E

Page 1: ...WARNING Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance An LP cyllinder not connected for use shall not be stored in the vicinity of t...

Page 2: ...54 or the International Fuel Gas Code 3 Keep the appliance area clear and free from combustible materials gasoline and other flammable vapors and liquids 4 Do not burn solid fuel in this appliance Do...

Page 3: ...ctrical See Fig 1 Please make sure that the electrical box and gas supply are located only within this area This will ensure that the final position of the unit will not be compromised Gas risers shou...

Page 4: ...embly 1 from fire pit body and carefully set aside 5 Carefully lift the fire pit and place it in its final position If there is a gas riser fire pit vessel should be placed so that the stub is enclose...

Page 5: ...embly 2 Control Box 3 Body 4 Gas and electrical supply NOTE Weather protection is required for power adapter Locate gas and power supply stubs at the outer most edge of the base cutout and as low as p...

Page 6: ...6 BENTO 42 E Owner and Installation Manual FIG 3 MINIMUM CLEARANCES TO COMBUSTIBLES CLEARANCE TO COMBUSTIBLES 72 72 12 17 BENTO 32 BENTO 42...

Page 7: ...shed glass or lava rock on top of burner media An uneven or excessively thick layer of topping can result in an uneven flame 6 Do not cover pilot shield Keep the lighting port open and free of media D...

Page 8: ...e to check for a leak Apply a mixture of liquid soap and water to all joints Bubbles forming on joints while the gas is running indicate a leak Correct all leaks at immediately Test Pressures in Exces...

Page 9: ...u Hr INLET PRESSURE MIN INLET PRESSURE MAX MANIFOLD PRESSURE ORIFICE SIZE BURNER PORTS PORT SIZE CIR E 18 69 000 4 5 W C 10 5 W C 3 5 W C 18 68 1 8 CIR E 18P 60 000 11 0 W C 13 0 W C 10 0 W C 37 68 1...

Page 10: ...ice technician to inspect the appliance and to replace any part of the control system and any gas control that has been under water Improper installation adjustment alteration service or maintenance c...

Page 11: ...upply gas control valve to the ON position 7 Plug the supplied AC adapter into a 110V power outlet 8 Connect the AC adapter to the AC input plug at the unit 9 Place Burner Assembly in Housing 10 To ig...

Page 12: ...e free of obstructions at all times Inspect area around the burner Remove any lint or foreign material with a brush or vacuum cleaner If it evident that the burner is damaged the burner must be replac...

Page 13: ...atural gas company 2 Separate the stones to allow more flame passage 3 Remove any foreign items from the flame pattern and or check for proper orifice sizing Burner is excessively noisy Note The movem...

Page 14: ...disconnected 1 Turn off gas supply or open manual shutoff valve 2 Purge air from the supply line 3 Clean pilot see Cleaning and Maintenance page 9 or replace pilot assembly 4 Check reconnect lead Burn...

Page 15: ...10 6 7 11 8 9 MAIN GND VALVE PILOT GND BURNER GND 24V SENSE SPARK AC POWER ADAPTER INPUT AC 120V 60 Hz 8A OUTPUT 24 VAC 750 mA CHASSIS GROUND PILOT NA410 OR LP410 IGNITION CONTROL BOARD CC 9120 30 GAS...

Page 16: ...i Orifice Control Box c w Cover Chassis Flex Connector Power Adapter 24 VAC 750 mA not shown 1 1 1 1 1 1 1 2 1 RBP018 PAN025 FLAT25 VNA017 O33018 CBCIR CHACIR FC6812 AC24 750 RBP018 PAN025 FLAT25 VLP0...

Page 17: ...17 BENTO 42 E Owner and Installation Manual 10 12 13 11 9 15 16 3 4 ILLUSTRATED PARTS LIST...

Page 18: ...llation instructions The Limited Lifetime Warranty will also be void if the appliance is not operated and maintained according to the operating instructions supplied with the appliance and does not ex...

Page 19: ...19 BENTO 42 E Owner and Installation Manual NOTES...

Reviews: