LIGHTING YOUR FIRE PIT

OPERATING INSTRUCTIONS

1.  STOP!  Read the safety information on pages 1, 2 and 8 of this 

manual.

2.  Turn off all electric power to the appliance.
3.  Do not attempt to light the pilot manually.
4.  Turn the supply gas control valve to the OFF position.
5.  Wait five (5) minutes to clear out any residual gas, then check for the 

smell of gas at and around the appliance, including near the floor.  If 

you smell gas, STOP!  Follow the instructions on page 1 of this 

manual.  If you do not smell gas, continue to the next step.

6.  Turn the supply gas control valve to the ON position.
7.  Plug the supplied AC adapter into a 110V power outlet.
8.  Connect the AC adapter to the AC input plug at the unit.
9.  Place Burner Assembly in Housing
10. To ignite buner, turn on electric power to the appliance.
11. To turn off appliance, turn off electric power to the appliance.

TURNING OFF THE GAS TO THE APPLIANCE

1.  Turn off all electric power supplied to the appliance if service is to 

be performed.  

2.  If necessary, remove the burner from the housing to access the 

manual gas valve.

3.  Turn the main manual shutoff valve to the full OFF position. Unplug 

the AC adapter from the power outlet.

WARNING:

This appliance is designed to be connected to a power 

source that is controllable by a switch.

Do not connect AC adapter to a live power source.

Summary of Contents for Bento 42 E

Page 1: ...WARNING Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance An LP cyllinder not connected for use shall not be stored in the vicinity of t...

Page 2: ...54 or the International Fuel Gas Code 3 Keep the appliance area clear and free from combustible materials gasoline and other flammable vapors and liquids 4 Do not burn solid fuel in this appliance Do...

Page 3: ...ctrical See Fig 1 Please make sure that the electrical box and gas supply are located only within this area This will ensure that the final position of the unit will not be compromised Gas risers shou...

Page 4: ...embly 1 from fire pit body and carefully set aside 5 Carefully lift the fire pit and place it in its final position If there is a gas riser fire pit vessel should be placed so that the stub is enclose...

Page 5: ...embly 2 Control Box 3 Body 4 Gas and electrical supply NOTE Weather protection is required for power adapter Locate gas and power supply stubs at the outer most edge of the base cutout and as low as p...

Page 6: ...6 BENTO 42 E Owner and Installation Manual FIG 3 MINIMUM CLEARANCES TO COMBUSTIBLES CLEARANCE TO COMBUSTIBLES 72 72 12 17 BENTO 32 BENTO 42...

Page 7: ...shed glass or lava rock on top of burner media An uneven or excessively thick layer of topping can result in an uneven flame 6 Do not cover pilot shield Keep the lighting port open and free of media D...

Page 8: ...e to check for a leak Apply a mixture of liquid soap and water to all joints Bubbles forming on joints while the gas is running indicate a leak Correct all leaks at immediately Test Pressures in Exces...

Page 9: ...u Hr INLET PRESSURE MIN INLET PRESSURE MAX MANIFOLD PRESSURE ORIFICE SIZE BURNER PORTS PORT SIZE CIR E 18 69 000 4 5 W C 10 5 W C 3 5 W C 18 68 1 8 CIR E 18P 60 000 11 0 W C 13 0 W C 10 0 W C 37 68 1...

Page 10: ...ice technician to inspect the appliance and to replace any part of the control system and any gas control that has been under water Improper installation adjustment alteration service or maintenance c...

Page 11: ...upply gas control valve to the ON position 7 Plug the supplied AC adapter into a 110V power outlet 8 Connect the AC adapter to the AC input plug at the unit 9 Place Burner Assembly in Housing 10 To ig...

Page 12: ...e free of obstructions at all times Inspect area around the burner Remove any lint or foreign material with a brush or vacuum cleaner If it evident that the burner is damaged the burner must be replac...

Page 13: ...atural gas company 2 Separate the stones to allow more flame passage 3 Remove any foreign items from the flame pattern and or check for proper orifice sizing Burner is excessively noisy Note The movem...

Page 14: ...disconnected 1 Turn off gas supply or open manual shutoff valve 2 Purge air from the supply line 3 Clean pilot see Cleaning and Maintenance page 9 or replace pilot assembly 4 Check reconnect lead Burn...

Page 15: ...10 6 7 11 8 9 MAIN GND VALVE PILOT GND BURNER GND 24V SENSE SPARK AC POWER ADAPTER INPUT AC 120V 60 Hz 8A OUTPUT 24 VAC 750 mA CHASSIS GROUND PILOT NA410 OR LP410 IGNITION CONTROL BOARD CC 9120 30 GAS...

Page 16: ...i Orifice Control Box c w Cover Chassis Flex Connector Power Adapter 24 VAC 750 mA not shown 1 1 1 1 1 1 1 2 1 RBP018 PAN025 FLAT25 VNA017 O33018 CBCIR CHACIR FC6812 AC24 750 RBP018 PAN025 FLAT25 VLP0...

Page 17: ...17 BENTO 42 E Owner and Installation Manual 10 12 13 11 9 15 16 3 4 ILLUSTRATED PARTS LIST...

Page 18: ...llation instructions The Limited Lifetime Warranty will also be void if the appliance is not operated and maintained according to the operating instructions supplied with the appliance and does not ex...

Page 19: ...19 BENTO 42 E Owner and Installation Manual NOTES...

Reviews: