background image

Hand Dryer 

Operating Instructions and Parts Manual 

Surface-mounted high speed hand dryer 

 

 

 

 

Diagnostics and Remedies

 

 

Symptom 

Corrective Actions for Initial Installation  Failures

 

If the dryer will not run

 

 

 

 

 

The dryer cycles by itself 

or runs constantly

 

The dryer makes a loud 

Noise and does not run 

for a complete cycle

 

 

The dryer runs but air 

stream is low pressure 

and/or low velocity

 

First ensure that the breaker supplying the dryer is operational. If it is, 

disconnect the power and remove the dryer cover. Taking suitable 

precautions to avoid shock hazard, reconnect the power and check for 

Voltage at the terminal block. Verify that connections are made correctly. 

Adjust the VR to make sure it is not set too low.

 

Ensure that there is no obstruction on or in front of the IR sensor. Clean 

any dirt or debris off the sensor lens. If problem persists, replace sensor.

 

Ensure that the supply Voltage is correct. Dryer will make a loud humming 

noise if the input Voltage is too high. Verify Voltage requirement on unit 

rating label and correct supply as required. If CBM has been damaged, 

replace CBM, IR sensor module and VR component and cable.

 

Ensure that the supply Voltage is correct. Dryer will run weakly if the 

input Voltage is too low.  Verify Voltage requirement on unit rating label 

and correct supply as required.

 

 

 

Symptom 

Corrective Actions for In-Service Failures

 

If the dryer will not run

 

 

 

 

 

 

The IR sensor only "sees" 

close range objects

 

 

 

 

The heater gets hot but 

no air stream is produced

 

The dryer only blows cold 

air during a full  cycle

 

 

The air stream is low 

pressure and velocity

 

First ensure that the breaker supplying the dryer is operational. If it is, 

disconnect the power and remove the dryer cover. Replace the CBM 

and IR sensor module. Test the VR for open circuit (see Technical 

Specifications for value). Replace VR if 

Ω

 = 

∞.

 Taking suitable precautions 

to avoid shock hazard, reconnect the power and check for Voltage at 

the terminal block.

 

Ensure that there is no obstruction on or in front of the IR sensor. Clean 

any dirt or debris off the sensor lens. If problem persists, disconnect the 

power and remove the dryer cover. Taking suitable precautions to avoid 

shock hazard, reconnect the power and try carefully adjusting the sensitivity 

control (yellow shaft in blue box on CBM) to increase the sensing range. 

If problem persists, replace sensor.

 

Disconnect the power. Remove the dryer cover and disassemble the blower- 
motor/fan housing. Replace the fan motor.

 

Disconnect the power. Remove the dryer cover and disassemble the blower- 

motor/fan housing. Test the thermostat for open circuit. Check the heater 

element for signs of burning or breakage. Damaged element must be replaced.

 

Check the output nozzle for obstructions. If none are present, disconnect 

the power. Remove the dryer cover. Remove any dust/lint buildup 

from intake vent slots. Disassemble the blower-motor/fan housing. 

Check the motor brushes for worn condition (

 

25/64" [10 mm] graphite 

remains) and replace them, if necessary.

 

 

 

5

 

HandDryerSupply.com   |   804-859-2498   |   [email protected]

Summary of Contents for HD-0960/0961-17

Page 1: ...PALMER FIXTURE COMPANY Hand Dryer Automatic Palmer Fixture Company P O Box 10887 Green Bay WI 54307 1 800 558 8678 www palmerfixture com HandDryerSupply com 804 859 2498 sales handdryersupply com...

Page 2: ...5 C Ambient Temp 77 F 25 C 44 2 63 6 CFM 75 108 m h 350 700W 12000 18000 R P M Adjustable Brush Type Dual Ball Bearings Auto Resetting Thermostat turns unit off 120V at 275 F 135 C 240V at 221 F 95 C...

Page 3: ...e a basin please make sure that reflection won t occur Type Y attachment If the power supply cord is damaged it must be replaced by the manufacturer or its service agent or a qualified person in order...

Page 4: ...For two or more dryers dryers should be no closer than 24 inches 610 mm on center 1 Remove and retain 2 cover screws and cover 2 Insert the power cord into the opening 4 Fix the base plate to the wal...

Page 5: ...ing screws Remove the cover Clean all dust lint from the interior of the dryer Do not flush with water Wipe the cover with a damp cloth and mild cleaning solution Do not Soak Never use abrasives to cl...

Page 6: ...close range objects The heater gets hot but no air stream is produced The dryer only blows cold air during a full cycle The air stream is low pressure and velocity First ensure that the breaker supply...

Page 7: ...yer Operating Instructions and Parts Manual Surface mounted high speed hand dryer 6 Diagram 3 4 5 6 7 8 1 9 11 19 20 2 12 21 13 22 14 15 23 16 17 18 HandDryerSupply com 804 859 2498 sales handdryersup...

Page 8: ...ottom 8 Heater element 120Vac 700W Heater element 240Vac 700W 9 Air outlet 10 LED assembly 11 Air outlet bracket 12 Circuit Board Module 110 120Vac Circuit Board Module 220 240Vac 13 Sensor bracket 14...