Installation manual
this case, the floor boards should not be attached very densely to avoid likely bulging. Leave some
space (1-2 mm) between the floor boards to allow for swelling. But if your climate is warm and dry, you
can install the boards densely because they will become drier and spaces may appear between them.
Storm braces
(NB! Not included in some house option kits!)
Attach the storm braces (if included in
the supplied kit) to the inner sides of
the front (2 units) and back (2 units)
walls with the supplied bolts. It is
important for the logs to be drilled
through in advance. Please keep the
distances indicated in the drawing so
that no problems occur due to wood
swelling or diminishing.
ADVICE
: Make sure that the storm
braces are attached to the apex log
from above and to the middle of the
first full-length wall log from below. If
necessary, shorten the upper ends of
the slats.
Do not turn the screws tightly so wood
can further swell or diminish.
With the house having settled, you
should adjust the attachments so the
wall logs can settle.
Installation of storm braces:
General advice:
Problem:
Gaps appear between the wall logs
Cause:
Additional details are attached to the house that do not allow wood to
swell/diminish.
Solutions:
If the door/window is attached to the wall logs with screws/nails, remove these
screws/nails;
If the storm brace is screwed on too tightly, loosen its attachment;
If (rain water) pipes are installed on the wall, loosen their attachments;
Problem:
The doors and windows become stuck.
Cause:
The house/foundation has settled.
Solution:
Check whether the house is level. Level the foundation joists and walls.
Cause:
The doors and windows have swelled due to moisture.
Solution:
Adjust the door and window hinges; if necessary, plane the door or window narrower.
We wish you total success with the garden house installation and much
joy with this house for many years to come!
Summary of Contents for FR19-3025
Page 5: ...234 254 279 311 6 3m ...
Page 6: ......
Page 7: ......
Page 8: ......
Page 9: ......
Page 10: ......
Page 11: ......
Page 12: ......
Page 13: ......
Page 14: ...EN Laying on concrete slabs not included FR Pose sur dalle béton non inclus 2790 2340 A B A B ...
Page 16: ...001 x14 007 x28 009 x28 001 009 007 007 009 ...
Page 20: ...RB1 1 x58 Ø2 5x50 x200 1 1 ...
Page 21: ...RE1 1 x2 x4 Ø2x16 x140 Ø3x30 x15 1 2 YPapp 1 RB1 1 RE1 1 Ø3x30 YPapp 1 2700 ...
Page 22: ...1 2 FaB3 1 x4 WB1 1 x4 Dia 1 x2 Ø3 5x40 x44 Ø2 1 FaB3 1 WB1 1 Dia 1 ...
Page 24: ...1 2 5 5 300 250 Ø3 5x25 Ø3 5x25 Ø4x16 Ø10 20mm Ø3 5x25 Ø2 1 Sla1 Ø4x16 Ø10 20mm ...